Struck by falling object or equipment, unspecified · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at Precision Fire Systems, Inc., 3135 S. Orange Ave, ORLANDO, FLORIDA 32806
on — Fractures, affecting the ankle(s).
Watch Precision Fire Systems, Inc. — freeGet an email when a new federal OSHA severe-injury report for Precision Fire Systems, Inc. is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee was walking down a corridor when a stack of drywall fell over and landed on the employee's left ankle fracturing it. The employee was hospitalized.
An employee was on a third floor balcony of an apartment building that was being built. He fell over a guardrail to the ground below, suffering broken vertebrae and a thumb injury. He was hospitalized.
An employee was unloading 30-foot 2-inch barrels from a pan holding about 20 barrels. The barrels tipped over, striking and breaking both of the employee's lower legs.
An employee was in a sandblasting area, preparing the surface of a plate heat exchanger frame for painting. The frame fell on the employee, who suffered fractures to vertebrae, the neck, pelvis, and rib cage; and punctured lungs.
A smoke jumper parachuted out of a helicopter during a forest fire response, landed on steep rugged terrain, and suffered femur and rib fractures and a liver laceration. The employee was hospitalized.
Employees were troubleshooting dual duct detectors in a room. The injured employee was on the second rung from the top of a forward-facing 12-foot A-frame ladder. He was reinstalling the duct detector in the furthest duct from him (18 inches). When he pushed the duct detector into the existing holes, the duct broke free and fell, striking his back and shoulders. He was knocked forward over the ladder and fell to the floor. The employee sustained a head injury.
An employee was descending an 8-foot A-frame ladder when he tripped over the fourth step/rung and fell, contacting the floor and a sprinkler pipe that was set on the ground. The employee sustained fractures to his left arm.
An employee working as a contracted firefighter was using a bulldozer to push back an active fire line when they became entrapped in flames, resulting in first- and second-degree burns.
An employee was engaging in daily physical training in preparation for fire season as a smokejumper. The employee sustained swelling and stiffness in their arms and was hospitalized with rhabdomyolysis.
An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.
An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.
An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.
An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.