Contact with hot objects or substances · Second degree heat (thermal) burns
At a glance
Federal OSHA recorded a severe workplace injury
at Brock Services, LLC., 9701 Manchester St., HOUSTON, TEXAS 77012
on — Second degree heat (thermal) burns, affecting the nonclassifiable.
Final narrative
A Brock employee was installing insulation in or near the vent drum of an aerator when hot water condensate released out of a steam line directly above the employee. The employee sustained second degree burns and was hospitalized.
An employee was adjusting the butterfly tip on an airless paint gun. The gun injected air and pressurized paint into the employee's left index finger, causing a laceration.
An employee was moving from a scaffold ladder to the scaffold platform when he fell to the ground 15 feet below. He suffered a broken right wrist and broken ribs.
An employee was descending a structural fixed ladder when the employee lost grip and fell approximately 10 feet to the lower level. The employee suffered fractures to the right and left ankles.
An employee was standing in an area where paint was stored, when a flash fire occurred. The employee suffered flash burns to her torso, arms, legs, and cheeks.
An employee was monitoring the loading of a railcar when he noticed a vent was leaking. He tried to close the secondary valve to isolate the leak. He put his safety harness on and pulled a probe up to close the valve and isolate the leak. When he pulled the probe up, he heard a pop. The vent hose blew off, spraying him with acetic acid. He suffered first and second degree burns to his lower legs and feet, requiring hospitalization.
An employee connected a steam line to a hose to clean equipment when the fitting broke loose. They were struck by steam in the left inner thigh, resulting in burns that required hospitalization.
An employee was making tea when she noticed tea grinds were collecting on the side and water was no longer dripping through the funnel. The employee was checking the funnel when boiling water and tea grinds spilled onto the left side of her body. The employee sustained burns to her neck, back, and arm.
An employee had turned off the ball valve on a waterpipe system and was removing the plug when the coupling system attached to the strainer came apart. Hot water sprayed on his arm and back, resulting in first- and second-degree burns that required surgery.
An employee was using a shovel to remove waste vermiculite from molten zinc. The metal had been placed in a bin and partially hardened. The employee broke through the partially hardened metal; still-molten metal flowed to the employee's steel-toed right boot and entered through the cloth boot tongue. The employee suffered a third-degree burn to the right foot and was hospitalized.
More severe injuries in this industry (NAICS 238990)
A crew was relocating a dumpster (containing approximately 200 pounds of demolished wire) to access the uninterruptible power supply (UPS) units they were servicing. During movement of the dumpster, a section of carpet tile dislodged from the floor, causing an employee to lose his footing, slip, and fall. He landed on his right wrist, resulting in a fracture.
An employee was cutting a board using a circular saw. The saw pinched, kicked back, and cut the employee's left ring and little fingers. The employee suffered an amputation to the little finger.
An employee was using an aluminum extension ladder to remove gutters at a height of approximately 20 feet. As they were removing the gutters, part of the gutter collapsed and struck the ladder, causing it to move sideways. The employee fell from the ladder and sustained fractures to ribs on the left side and their right forearm.
An employee was using an electric saw to cut a piece of wood for a fence. The saw slipped out of his hand and lacerated his left leg. He was hospitalized.
An employee was erecting a scaffold. A side bracket was not secure. The employee stepped on the bracket to test it and fell 18 feet to the concrete floor resulting in fractures to the ankles and femurs. He was not using fall protection equipment.
After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.
An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.
An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.