Caught in running equipment or machinery during regular operation · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at Clark Equipment Company, 210 First Avenue NE, GWINNER, NORTH DAKOTA 58040
on — Amputations, affecting the fingertip(s).
Final narrative
An employee was operating a hydraulic jig and positioning a plate for tack welding when the hydraulic ram actuated the swing clamp. The swing clamp amputated the employee's right pinky fingertip.
AmputationFingertip(s)Metal, woodworking, and special material machinery, unspecified
Two employees were operating the welding jig. When one employee activated the two hand controls, the injured employee's hands were between the part and jig, resulting in a partial amputation to the injured employee's left little finger.
An employee was attempting to adjust a tote on a cart when one of the tote legs slid down and sheared off two of his fingertips between the tote and cart.
An employee was sharpening peeler blades when their shirt was caught in the grinding wheel. The employee sustained tendon damage and a crushed right hand.
An employee was preparing to cut lumber on a panel saw when the clamp engaged and caught the employee's left middle finger, resulting in a fingertip amputation.
More severe injuries in this industry (NAICS 333120)
An employee was working behind a stack of steel I-beams (stacked 2 columns deep and 4 levels high on the floor) while a forklift was pushing the stack. When the forklift took off the second-to-last beam, the last one was pushed over, causing it to fall to the ground and strike the employee. The employee sustained a fracture to the right leg.
An employee was lifting a flat sub (sheet steel) in the flats robot cell (weld area). He was operating a hoist when his left little fingertip got caught between the lifting device hook and the flat sub. The employee sustained a partial transphalangeal amputation.
An employee was underneath a 35-foot boom truck and adjusting the transmission linkage when the truck jumped over the wheel chocks and rolled over the employee's right leg, resulting in a fracture.
A crane was being used to lift a debris tank from a rack. The tank crushed the employee's right hand, causing amputations to the employee's right ring finger and little fingertip.
An employee was removing a small sheet metal part out of the die of the brake press. The foot pedal was pressed, causing the part to lift and crush their left thumb against the die. The employee suffered an amputation to the thumb tip including the loss of flesh and the fingernail.
An employee was on the ground working to close a trailer door. The door was caught by the wind and blew the employee backward. He landed on his back and sustained four fractured ribs, requiring hospitalization.
An employee was walking on top of boiler to close a valve. The employee fell off the boiler and landed on the floor, sustaining fractured ribs. The employee was hospitalized.
An employee was exiting a loader and coming down the ladder. His hand slipped off the railing and he fell backward onto sandy ground, landing on his side. The employee was hospitalized with a fractured pelvis and a rotator cuff tear.