Struck by discharged object or substance · Cuts, lacerations
At a glance
Federal OSHA recorded a severe workplace injury
at Cal-Maine Foods, Inc., 180 North Church Street, BLACKSHEAR, GEORGIA 31516
on — Cuts, lacerations, affecting the finger(s), fingernail(s), unspecified.
Final narrative
Two employees were unclogging a drain at a building's wastewater system. One employee was using a hose plugged into a pressure washer; the hose burst and high-pressure water lacerated the other employee's index finger.
An employee was doing housekeeping work inside a chicken house. The employee missed a step onto a walkway near the exit, fell into an 8-foot-deep pit, and landed on its concrete floor. The employee suffered a leg fracture above the ankle, as well as a chin laceration.
An employee was hospitalized after he was found lying on a warehouse floor, bleeding from his nose and right ear. The employee sustained a depressed skull fracture on the right side of his head, multiple dislocated cervical fractures, a laceration to his right ear, a fracture to his right scapula tip, and wedge compression fractures to his T2 and T4 vertebrae.
An employee was troubleshooting a conveyor belt when their fingers became caught in a drive chain. The employee sustained an amputation of the right index fingertip.
A maintenance employee was repairing a torn belt on a belt conveyor and contacted an energized wire. The employee sustained burn injuries from electric shock and was hospitalized.
An employee was repairing a water pump on a lawn mower. He replaced the water pump and thermometer and then went to test drive it. The mower started running hot, so he brought it back to the shop and opened the hood on the mower. The radiator overflowed the bottle, the lid blew off, and hot coolant sprayed the employee's face, eyes, and neck. The employee was hospitalized for burns.
An employee was installing wood trim surrounding a skylight inside a home. While holding a piece of trim in it's desired location, his pneumatic nail gun discharged, sending a 3/4-inch pin nail into his left forearm.
An employee removed a safety valve on a trailer that unknowingly contained nitrogen gas. The gas released from the trailer and pushed the employee backward off a scaffold approximately 10 feet before they struck a garage door, resulting in a pelvic injury.
An employee was sitting at her workstation when a nail gun malfunctioned and shot a nail into her left leg. She suffered a puncture and blood vessel injury and was hospitalized.
On November 25, 2023, an employee was using a high-pressured water hose to perform sewer line cleaning operations. The employee's right little finger and palm were lacerated by pressurized water from the hose.
Three employees were transferring a metal lid using a manual chain hoist to place it onto a cart. While they were adjusting its position, the lid shifted and the injured employee's left hand became caught between the hoist hook and the handle, resulting in a laceration and amputation of their ring fingertip including the tuft.
An employee was using an 8-foot metal pipe to remove a manure blockage at the transfer to an incline conveyer. The employee s left hand was placed on top of the pipe while removing the blockage. The pipe pushed their left hand into the wooden railing of the platform they were standing on, catching their thumb in a pinch point and resulting in partial amputation.
An employee was driving a farm truck with the dump box raised when he went through a farm building accessway and the dump box struck the entryway of the building. The truck lifted up and came back down, jolting the employee. The employee sustained a back injury.
An employee was doing housekeeping work inside a chicken house. The employee missed a step onto a walkway near the exit, fell into an 8-foot-deep pit, and landed on its concrete floor. The employee suffered a leg fracture above the ankle, as well as a chin laceration.
An employee was troubleshooting a manure belt to figure out why it kept turning off. The employee's right hand was pulled into the drive and compression roller of the long belt in the manure belt system, resulting in numerous injuries to their hand and forearm, including a partial amputation of the middle finger and a degloved palm.
An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.
During a workshop meeting in a hotel, an employee heard a drilling noise, so he walked outside to see what it was. An explosion occurred (possible gas line) and his face, ear, and hair were burned. He also fell and sustained a pelvic fracture.
An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.