105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

North Star EnergySsolutions LLC

Direct exposure to electricity, unspecified · Electrical burns, unspecified

Federal OSHA recorded a severe workplace injury at North Star EnergySsolutions LLC, Town Square Blvd @ Lavender Dr., DEL RIO, TEXAS 78842 on — Electrical burns, unspecified, affecting the hand(s), unspecified.

Watch North Star EnergySsolutions LLC — free Get an email when a new federal OSHA severe-injury report for North Star EnergySsolutions LLC is published. One employer, no account, unsubscribe in one click.

An employee came into contact with live electrical cable, suffering burns to both hands.

Hospitalized Hand(s), unspecified Electrical wiring-building

Bob Woodall Air Care Systems, Inc.

An employee was installing a 15-amp breaker in an electrical panel when a 12-gauge ground wire touched the positive busbar of the panel, resulting in an arc flash. The employee sustained a second-degree burn to their left hand.

Amentum Spaceport LLC

An employee was repairing an HVAC system in the drop tile ceiling of a conference room when they were shocked, causing them to fall from the ladder. The employee sustained burns to their right middle and ring fingers.

Marsh Bellofram Corporation

An employee was replacing a contactor inside an electrical panel attached directly to a press. The press itself was receiving power from another main panel. After replacing the contactor, the employee flipped the switch and an arc flash occurred, burning the employee's elbow, bicep, and neck.

Heart Utilities of Jacksonville, Inc.

An employee was attempting to switch a medium-voltage primary cable and install a 200-amp fuse barrel. The employee contacted the bottom of the switch gear cradle for the fuse barrel, causing an arc blast. The electricity entered the employee s left hand and exited his big toes, resulting in electric shock and burns to the left hand, arm, shoulder, and both feet. The employee was hospitalized.

Duke Energy Florida, LLC

On December 6, 2023, an employee of Duke Energy was working on a single-phase 120-/240-volt parallel service re-tap when a secondary flash occurred in an underground service. The employee suffered a second-degree burn to the face and was hospitalized.

Campos EPC, LLC

An employee was walking when he tripped on a small mound of dirt, fell, and sustained a fractured leg.

Tennessee Valley Authority

An employee was polishing the center of a try bar on a lathe when they sustained an avulsion of the right forearm that required surgery.

Ty Energy Services LLC

An employee was operating a dump truck when the trailer door swung and pinched the employee's right middle fingertip underneath the nailbed, resulting in an amputation.

TESLA ENERGY OPERATIONS, INC.

An employee was attaching a turnbuckle to an auger. The turnbuckle slipped and the employee's left thumb was pinched between the turnbuckle and the auger resulting in a partial amputation of left thumb.

T G Meat Center LLC

After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.

Professional Flooring Supply

An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.

EnviroSafe Demil LLC

An employee was inspecting flares processes. The employee received burns to the front side of the body, face and arm from the flares.

Inteplast Group

An employee was removing plastic material from a production line when the machine cycled and amputated his left index, ring, and little fingers.

Regency IHS of Fairwinds Halletsville, LLC

An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.