Ignition of vapors, gases, or liquids · Heat (thermal) burns, unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Okuley's Pharmacy & Home Medical, Inc., 1201 E. Second St., DEFIANCE, OHIO 43512
on — Heat (thermal) burns, unspecified, affecting the multiple body parts, n.e.c..
Final narrative
On April 15, 2020, an employee was using an ethanol filter to make sanitizer. As the employee was using a pump to filter ethanol from one 5-gallon bucket (through tubing and a charcoal filter) to another, the ethanol started to spray out and immediately caught fire. The employee suffered second-degree burns to the face, hands, and arms.
An employee was cleaning a cordless drill. As they applied brake fluid to the drill and pulled the trigger, the fluid ignited. The employee suffered burns to the face, hands, and arms.
An employee was spraying glue to the floor of an enclosed cargo trailer. The fumes made contact with the heater causing a flash fire. The employee suffered burns to their face and right hand.
An employee was replacing a valve in the gas line to the fryer. The shutoff valve malfunctioned resulting in a gas leak that then ignited. The employee sustained burns requiring hospitalization.
An employee was loading cardboard into a cardboard bailer to be compressed. The machine began to operate with the door open, and the employee's left hand was fractured.
An employee was walking to their car after work. They tripped over a concrete parking stop and fell in the parking lot. The employee was hospitalized with a concussion.
An employee was putting a box onto a cart when a handle on the box broke and the cart began to roll away from her. She lost her balance, fell with the box still in her hands, and broke her left hip. She was hospitalized.
An employee was working to deliver mail to an apartment building. She was waiting for a customer to move, to obtain clearance to the mailboxes. The door swung inward and closed on her right little finger. The top half of her finger was surgically amputated.
An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.
On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.
An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.
An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.