Injured by slipping or swinging object held by injured worker · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at One Wind Services Inc., 2435 State Route 49, WESTFIELD, PENNSYLVANIA 16927
on — Amputations, affecting the finger(s), fingernail(s), n.e.c..
Final narrative
An employee was torqueing bolts with a hydraulic torque wrench inside a wind turbine. The employee was reaching to clear plastic debris from between the bolt and the wrench when the wrench actuated, crushing his right little finger and ring finger. He suffered an amputation to the little finger (6 millimeters from the nail); the injury to the ring finger required stitches.
An employee was operating a lift inside a wind turbine. He was outside of the lift when it moved and crushed his left arm between it and a rung. His arm broke and required surgery.
An employee was using a saw to cut a piece of concrete when the piece gave way and pushed the saw into the employee's leg. The employee's leg was lacerated, requiring stitches and hospitalization.
An employee was grinding some hardfacing on a bulldozer blade when the 9-inch grinder kicked back and lacerated his left leg above the knee. The employee was hospitalized and required surgery.
An employee was operating a rotating tool to place thread protectors on the end of pipe. Her left hand was on the rotating part of the tool when the tool engaged, resulting in a left forearm fracture and a thumb laceration.
More severe injuries in this industry (NAICS 221115)
Two employees were removing a circuit breaker. The injured employee was using wrenches in the removal process. One of the wrenches contacted an adjacent door, resulting in an arc flash. The employee suffered burns to their neck, face, and ear, as well as momentary vision loss due to the flash.
An employee was ascending the wind tower when their right arm was caught between the lift and the ladder. The employee sustained a right elbow injury and was hospitalized.
On 3/27/2025, at 9:57 AM, an employee was performing switching work including installing electrical grounds when an arc flash occurred. Personal protective equipment (PPE) was worn at the time, including an arc flash hood, shirt, and pants. The employee suffered burns and was hospitalized.
An employee was cleaning dirt out of a contactor using a hand-held blower and contact cleaner. An arc flash occurred, and the employee sustained burns to the right side of their face and both hands.
On February 16, 2025, an employee was descending a ladder on the third deck after completing rigging at a wind farm. Their left foot slipped on the penultimate rung and their leg became wedged between the ladder rungs and a horizontal bracket. The employee then landed on the second deck resting platform, resulting in a leg fracture above the ankle.
An employee was walking into the motor control center (MCC) room when his right ring finger was caught in the hinge of a doorway. He sustained an open phalanx fracture, which resulted in a partial amputation above the first knuckle.
An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.
An employee was pulling down a broken skid with a forklift. When the employee backed up the forklift to get the forks out of the skid he pulled down, he contacted the forks of another parked forklift, fracturing both of his legs. He was hospitalized.
An employee was carrying cups back to the kitchen when her foot got caught on a cart and she fell face-first. During the fall, a piece of glass from a cup cut the inside of her mouth, severing an artery. She also sustained a laceration on her lower lip. The employee was hospitalized.