Ignition of vapors, gases, or liquids · Heat (thermal) burns, unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at E & M Services LLC, Norht Dakota HWY 23 Mile marker 19, WATFORD CITY, NORTH DAKOTA 58854
on — Heat (thermal) burns, unspecified, affecting the multiple body parts, n.e.c..
Final narrative
An employee was performing maintenance and starting a gas plant by turning the valves when a flash fire and explosion occurred. He suffered burn injuries to his hands and face.
HospitalizedMultiple body parts, n.e.c.Coal, natural gas, petroleum fuels and products, unspecified
An employee was unloading pipes from a trailer. A pipe (3.5 inch in diameter) rolled off the trailer and struck the employee's legs. The employee sustained a right leg fracture.
An employee was cleaning a cordless drill. As they applied brake fluid to the drill and pulled the trigger, the fluid ignited. The employee suffered burns to the face, hands, and arms.
An employee was spraying glue to the floor of an enclosed cargo trailer. The fumes made contact with the heater causing a flash fire. The employee suffered burns to their face and right hand.
An employee was replacing a valve in the gas line to the fryer. The shutoff valve malfunctioned resulting in a gas leak that then ignited. The employee sustained burns requiring hospitalization.
An employee had been cleaning the work area. While lifting a saw, the employee's index finger was lacerated by the saw blade. A tendon was cut and required surgery.
An employee was delivering home heating fuel when bees came from the ground and stung the employee's face, neck, torso, and hands. The employee proceeded to shut off the oil flow before losing consciousness. They were hospitalized due to an anaphylactic reaction.
An employee was using a torch to loosen a bolt on a water trailer. Natural gas was present in the water and it ignited, causing a fire. The employee sustained third-degree burns to their upper leg.
An employee had been conducting crane operations. The employee went to stop a piece of oil and gas equipment for tubular running from falling over to the ground. Their right hand was caught between a rolling ladder and the equipment, resulting in fractures to the index and middle fingers. They were hospitalized and the middle finger required surgery.
An employee was working to install a drive belt on a water pump. He was holding the belt on both sides of the pulley, working to route it over the top. As he pulled down with his right hand, the pulley rotated and the belt slid over it, pulling his left little finger between the pulley and the belt. He suffered an amputation to the fingertip as well as a fracture to the ring finger.
An employee was on the ground working to close a trailer door. The door was caught by the wind and blew the employee backward. He landed on his back and sustained four fractured ribs, requiring hospitalization.
An employee was walking on top of boiler to close a valve. The employee fell off the boiler and landed on the floor, sustaining fractured ribs. The employee was hospitalized.
An employee was exiting a loader and coming down the ladder. His hand slipped off the railing and he fell backward onto sandy ground, landing on his side. The employee was hospitalized with a fractured pelvis and a rotator cuff tear.