Caught in running equipment or machinery during maintenance, cleaning · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at PHD MANUFACTURING, 44018 COLUMBIANA-WATERFORD RD, COLUMBIANA, OHIO 44408
on — Amputations, affecting the finger(s), fingernail(s), unspecified.
Final narrative
An employee was trying to unjam a pulley on a forming machine when the wire rope on the pulley let go and pulled her thumb under it, causing a partial amputation.
Two employees were repairing the hydraulic engagement pins on a rented front-end wheel loader. The machine controls were activated to move the attachment pins and an employee's finger was caught between the pins and the bushings. Their right index finger was partially amputated.
An employee was cleaning the conveyor on a piece of equipment when they slipped and their right hand was pulled into the chain sprocket. The employee's fifth fingertip was amputated.
An employee was throwing blankets onto a blanket folding and stacking machine. A blanket got stuck in the machine and she attempted to remove it when the machine contacted her right little finger, resulting in a fingertip amputation.
More severe injuries in this industry (NAICS 332919)
An employee was troubleshooting a shell core machine that had failed to raise the sand hopper into place for core making. The employee went to manipulate a switch and the machine cycled. The employee s left middle fingertip was caught between the roller-ball switch and the roller-ball switch target, resulting in a laceration that required surgical amputation to part of the distal phalanx.
On August 18, 2025, at approximately 7:40 AM, an employee utilized a pocket knife to cut banding on a new bundle of rod material. The knife blade bent during use. The employee was working to straighten the blade on a hard surface when the knife slipped, causing a lacerating their right wrist/forearm. The employee was hospitalized.
An employee was manually pulling drive belts to rotate a machine that needed repair. The employee's right index finger was pinched between a rubber drive belt and a pulley, causing an amputation to the fingertip.
At about 9:15 a.m. on May 14, 2025, an employee was using a bending press to bend metal into a U shape. The press caused an amputation to the employee's left middle finger.
An employee was running a test pipe for 12 feet and went to pull the pipe out of a roll grooving tool. As he was doing this, the tool's control pedal actuated, causing the tool to rotate. The employee's glove became caught and was pulled into the rollset, amputating about half an inch of his index finger.
An employee was working to deliver mail to an apartment building. She was waiting for a customer to move, to obtain clearance to the mailboxes. The door swung inward and closed on her right little finger. The top half of her finger was surgically amputated.
An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.
On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.
An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.
An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.