Struck against moving part of machinery or equipment · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at CURTIS PACKING CO., 115 Sycamore St., TIFTON, GEORGIA 31794
on — Amputations, affecting the finger(s), fingernail(s), n.e.c..
Final narrative
An employee was cutting pork loins with a bandsaw. The sawblade amputated the employee's left little finger at the first knuckle.
An employee was on a metal ladder straightening boxes on top of a five-foot rack. He lost his balance and jumped two to three feet off the ladder landing on the concrete floor and shattering bones in his right ankle and leg.
An employee was operating a strip saw. As the employee shut off the saw, their right index and middle fingertips were amputated by the blade before it came to a complete stop.
An employee was using a table saw to cut a piece of wood for wall framing. The wood jumped, causing the employee's hand to move toward the saw, amputating their left index finger and causing a laceration on their hand.
An employee was operating a trim saw. While trying to free a jammed board she had just cut, she came into contact with the running saw blade, which amputated her right thumb.
After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.
An employee was using a de-clipping machine to cut the metal clips off of sausage sticks. As the employee put a link of sausages into the machine, their hand slipped into the point of operation. A piston pinched the employee's left index finger, causing a partial amputation.
An employee was operating a small tabletop grinder in a food safety quality assurance lab. She was stuffing meat down the grinder's chute when the grinder caught her right hand. Its auger caused an amputation to her middle finger and a partial amputation to her index finger.
A maintenance employee was removing an inspection plate from an industrial cooker. Hot liquid spilled onto him and burned his hands, arms, and torso area. He was hospitalized.
An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.
During a workshop meeting in a hotel, an employee heard a drilling noise, so he walked outside to see what it was. An explosion occurred (possible gas line) and his face, ear, and hair were burned. He also fell and sustained a pelvic fracture.
An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.