Other fall to lower level, unspecified · Intracranial injuries, unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at AEP-PSO, 7300 E HWY 88, OOLOGAH, OKLAHOMA 74053
on — Intracranial injuries, unspecified, affecting the brain.
Final narrative
An employee was climbing a step ladder when the ladder was kicked out from underneath him, causing him to fall and hit the right side of his head on the ground below.
An employee was on an A-frame ladder retrieving materials from a shelf. He slipped and fell and his leg got caught in the ladder rungs, breaking his left tibia.
An employee was unloading materials from a flatbed trailer when they fell from the trailer and landed on the ground. The employee sustained a fractured left leg.
An employee was unloading appliances at a customer location for delivery. The employee was moving a water heater to be placed on the liftgate when he stepped backward and fell to the ground. The employee sustained rib and back injuries.
An employee was performing troubleshooting and maintenance on one of the generators that feed the RF line for glue-laminated timber (glulam) beam production. He was reattaching the outer panel of the generator. A circuit was completed and the employee was electrocuted by the generator and sustained burns. The employee was hospitalized.
An employee was utilizing a utility task vehicle (UTV) to patrol a 138 kV transmission line in a right-of-way. The UTV drove into a washout hole that was approximately 6 feet deep and obstructed by vegetation. The employee sustained a dislocated shoulder, a fractured left humerus, back pain, and a strained ankle. He was hospitalized.
A crew of employees were working to replace a utility pole that was broken by a motor vehicle accident. As the crew was removing equipment from the broken pole, part of the pole broke, fell on the injured employee, and rolled over him. The employee sustained two broken shoulders, multiple broken ribs, and a damaged lung that required hospitalization and surgery.
An Ameren lineman was making secondary voltage connections in a pad-mounted residential feed transformer. The lineman contacted an energized lead bushing, sustained an electrical shock, and was hospitalized.
An employee was helping to move a 1,300-pound coil on a cart. The steel caster hit a crack in the concrete, the weld holding the caster onto the cart broke, and the coil and cart tipped over onto the employee. He was hospitalized with a laceration on his forehead and a pelvic fracture on his right side.
An employee was working in the food service warehouse when he experienced chest pain, difficulty breathing, and lost consciousness. The employee sustained carbon monoxide poisoning.
An employee was cutting a piece of metal rod with a metal cutting machine. His right middle finger became caught between the rod and the machine's table. The employee's fingertip was partially amputated.
An employee was working at her desk. She went to stand up and fell to the floor beside the desk. The employee sustained a hip displacement and required surgery.
An employee was processing wood boards at a chop saw when the saw malfunctioned and the blade cut her left hand and fingers. She was hospitalized and her little finger was surgically amputated.