Struck by falling object or equipment, n.e.c. · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at Pennsylvania Transformer Technology, Inc., 30 Curry Avenue, CANONSBURG, PENNSYLVANIA 15317
on — Fractures, affecting the lower leg(s).
Final narrative
An employee was moving a steel coil that was 4.5" in width and weighed 1,340 lbs. from where it was being stored to the machine using an overhead crane. As the employee was attempting to roll the steel coil out from where it was stored to attach it to the crane, it started to become off balance and tipped over, landing on the employee's legs. The employee was trapped under the steel coil and sustained a broken tibia and fibula that required surgery.
An employee was working from the top platform of a portable stair tower. While reaching in the direction of the stairs, the employee fell approximately 5 feet to the ground below and sustained a broken ankle.
An employee was moving a piece of an I-beam for welding when it rolled off the cribbing. The employee went to catch it when it fell and crushed the employee's finger, resulting in a partial amputation.
An employee was helping to disassemble large reels used to store steel wire when a 264-pound flange from the reel fell over onto the employee's left leg. The employee sustained multiple fractures to their leg and ligament injuries to the lower leg.
The injured employee was putting away materials on the warehouse floor as a co-worker was pushing a pallet onto a nearby shelf. The pallet knocked another pallet forward, causing it to fall onto the injured employee's shoulders. The employee suffered fractures in their right and left knees and ankles.
Employees were moving a single man lift into a building and reclining the lift to position it to fit through the door. The lift shifted and fell, causing the employee to sustain fractures to the left tibia and fibula. The employee was hospitalized and had surgery.
An employee was moving a light tower so it could be hitched to a truck. He grabbed the tongue of the trailer hitch on the light tower to slide it to the left. The tongue jack fell off, causing the light tower tongue to drop on the employee's right hand. The employee's middle fingertip was amputated.
More severe injuries in this industry (NAICS 335311)
An employee was checking a pole-type transformer tank for leaks. A hydraulic clamping device was lowered onto his right thumb and crushed it against the sharp edge of the bottom of the tank. He suffered a partial transphalangeal amputation to the thumb.
An employee was troubleshooting a machine. He was investigating a slipping belt when it caught his left hand and pulled it into a pulley, partially amputating the tip of his thumb.
An employee was tilting a radiator in a fixture. The radiator moved in the fixture and crushed the employee's left index fingertip, causing an amputation.
An employee installed a busbar on a coil for a winding machine. The busbar hit a tension bar, causing his left ring finger to get caught between the coil and the tension bar, which pulled in the employee's glove and resulted in a medical fingertip amputation. The machine was guarded at the time.
An employee was operating a wire winding machine when their clothing was caught in a rotating component, pulling them into the equipment. The employee's right arm was fractured.
An employee was walking into the motor control center (MCC) room when his right ring finger was caught in the hinge of a doorway. He sustained an open phalanx fracture, which resulted in a partial amputation above the first knuckle.
An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.
An employee was pulling down a broken skid with a forklift. When the employee backed up the forklift to get the forks out of the skid he pulled down, he contacted the forks of another parked forklift, fracturing both of his legs. He was hospitalized.
An employee was carrying cups back to the kitchen when her foot got caught on a cart and she fell face-first. During the fall, a piece of glass from a cup cut the inside of her mouth, severing an artery. She also sustained a laceration on her lower lip. The employee was hospitalized.