Geosearch, Inc.

Indirect exposure to electricity, unspecified · Electrical burns, unspecified

Federal OSHA recorded a severe workplace injury at Geosearch, Inc., 50 Westford Rd., TYNGSBORO, MASSACHUSETTS 01879 on — Electrical burns, unspecified, affecting the nonclassifiable.

An employee was fueling a mobile drill rig. When lifted, the drill boom contacted an overhead powerline. The employee was shocked, suffering a small pinhole burn.

Hospitalized Nonclassifiable Drilling machines, drilling augers

AAXIOM CONCRETE SAWING, LLC

An employee was coring a concrete slab when their drill contacted a live electrical conduit. The employee suffered an electrical shock.

D-T Steel Inc

An employee was welding clips onto the end of the bridging of a wall, then installing bolts through the clips to the wall. As the employee lowered his rod holder down into the lift basket, the rod contacted the basket and energized it. As the employee leaned forward, they contacted the basket and grounded joist, resulting in first- and second-degree electrical burns to the stomach, back, and arms.

High Country Line Construction Inc

An employee was on the ground preparing to receive a wire stringing steel rope being flown by a helicopter. The employee grabbed the steel line and was shocked by electricity from the line on his right hand. The employee was hospitalized and required surgery for nerve damage to his hand.

Ernest P. Breaux Electrical, Inc.

An employee was pulling a line through a light pole when it contacted an uninsulated line. The employee was shocked and sustained burns that required hospitalization.

West Penn Power

An employee was in a bucket truck drilling a hole into a utility pole when a conductor located above the employee broke free from the pole and fell onto the equipment. The employee suffered second-degree burns to the right side of their face.

VILLAGER CONSTRUCTION, INC.

An employee was directing trucks as they entered and left a highway work zone. A vehicle struck them, resulting in multiple fractures and other injuries. The employee was hospitalized.

Bucket Enterprises LLC

An employee was assisting the crew with patching and restoring a roadway after the installation of a sewer line. He was helping place and level the blacktop/backfill material over the trench area to bring the road surface back to proper grade. The employee was walking between a forward-moving dump truck and a dirt pile when his right foot was run over by the truck s wheel, causing him to fall. The employee sustained injury to his foot.

RJV Construction

An employee was rigging I-beams. An I-beam slid off the stack of I-beams and fractured the employee's leg.

Lindamood Demolition, Inc.

An employee was operating a skid steer with a bucket attachment at a demolition site. While driving it to the rear of the property to park it, the employee came into contact with a live electrical transformer unit that was located outside of the facility. The employee sustained electrical burns on his hands extending up to his elbows and a fractured ankle.

Gerke Excavating, Inc.

An employee was installing a door on a semi-trailer. They were using a forklift to lift the door to the height of the trailer when the door became jammed between the forklift mast and the hinge on the trailer. When the employee went to dislodge the door from the mast, the door fell and crushed their foot. Their big toe was amputated. The employee was hospitalized and their big toe was surgically reattached. The employee's foot and other toes also required surgery.

A&S Services Group

An employee fell while exiting a trailer. The employee landed on their left side on the pavement, suffering multiple broken ribs on the left side. The employee was hospitalized.

American Flowform and Machining, LLC

Two employees were setting up a mandrel in the spindle of a machine. The mandrel was side-shifted while an employee's hand was on the mast of a powered industrial truck. The employee suffered crushing injuries that resulted in amputations to the middle and ring fingertips.

Acushnet Rubber Company, Inc

An employee had been loading a double deck press. The employee saw a mold had been sent in with the C-hook still attached on the belly bar. As he went to remove the hook from the mold, his right thumb got caught on the C-hook. The employee's thumb was partially amputated.

Warner Brothers, LLC

An employee was operating a roller and paving a small pathway next to a pavilion. The ground was on a slight pitch, causing him to reach up toward the roll cage to stabilize himself. His right fifth finger was pinched between the roll cage and the rafter of the pavilion. The employee sustained a partial degloving injury with partial traumatic amputation.

Roby's Propane Gas

An employee was delivering home heating fuel when bees came from the ground and stung the employee's face, neck, torso, and hands. The employee proceeded to shut off the oil flow before losing consciousness. They were hospitalized due to an anaphylactic reaction.