Alder Vegetation Group

Direct exposure to electricity, unspecified · Electrocutions, electric shocks

Federal OSHA recorded a severe workplace injury at Alder Vegetation Group, Myles Rd, WHITE CASTLE, LOUISIANA 70788 on — Electrocutions, electric shocks, affecting the bODY SYSTEMS.

Watch Alder Vegetation Group — free Get an email when a new federal OSHA severe-injury report for Alder Vegetation Group is published. One employer, no account, unsubscribe in one click.

An employee was working in an aerial bucket lift when his left shoulder contacted an energized overhead wire. He was hospitalized, undergoing surgery to the shoulder.

Hospitalized BODY SYSTEMS Power lines, transformers, convertors

Bob Woodall Air Care Systems, Inc.

An employee was installing a 15-amp breaker in an electrical panel when a 12-gauge ground wire touched the positive busbar of the panel, resulting in an arc flash. The employee sustained a second-degree burn to their left hand.

Amentum Spaceport LLC

An employee was repairing an HVAC system in the drop tile ceiling of a conference room when they were shocked, causing them to fall from the ladder. The employee sustained burns to their right middle and ring fingers.

Marsh Bellofram Corporation

An employee was replacing a contactor inside an electrical panel attached directly to a press. The press itself was receiving power from another main panel. After replacing the contactor, the employee flipped the switch and an arc flash occurred, burning the employee's elbow, bicep, and neck.

Heart Utilities of Jacksonville, Inc.

An employee was attempting to switch a medium-voltage primary cable and install a 200-amp fuse barrel. The employee contacted the bottom of the switch gear cradle for the fuse barrel, causing an arc blast. The electricity entered the employee s left hand and exited his big toes, resulting in electric shock and burns to the left hand, arm, shoulder, and both feet. The employee was hospitalized.

Duke Energy Florida, LLC

On December 6, 2023, an employee of Duke Energy was working on a single-phase 120-/240-volt parallel service re-tap when a secondary flash occurred in an underground service. The employee suffered a second-degree burn to the face and was hospitalized.

Garden Angels New York LLC

An employee was cleaning leaves with a backpack blower when he fell from a ladder, resulting in injuries to his head, neck, and back.

Advanced Mulch Inc

An employee was helping to set up a mulch blowing truck when they were struck by an oncoming vehicle. The employee was hospitalized with a fractured knee, a concussion, and a head laceration; they also received stitches on their arm.

4 Seasons Property Services, Inc.

An employee was rappelling down a tree. When he was most of the way down, he fell on the ground and suffered a broken pelvis.

Boston Land Co Management Services Inc

An employee was using a table saw to cut a piece of wood when the saw cut his thumb, index, and middle fingers. His index finger was amputated and he was hospitalized.

Parm's Landscape Management

An employee was mowing a residential lawn at a client's house. The mower slid on the land and tipped over onto him. The employee was hospitalized with a fractured vertebra in the neck and partial paralysis.

Kisatchie Midnight Express

A driver was exiting his vehicle outside the plant gate when his foot slipped on the top step of the truck. He fell to the ground, landed on his left hip and elbow. The employee was hospitalized with a fractured hip/femur.

CHRISTUS St. Frances Cabrini Hospital

A security employee was responding to an urgent call from staff regarding a violent patient. The employee tripped and fell on the floor outside of the stairwell. The employee sustained a closed head injury, contusion of the cerebrum without loss of consciousness, and a closed fracture of the distal end of the right radius.

Jean Simpson Personnel Services, Inc.

A temporary employee was testing an electrical starter motor. He was placing tape on the starter while the breaker was not engaged, but the starter sent an arc flash that burned his hands and stomach.