Chemtex, LLC

Caught in running equipment or machinery during maintenance, cleaning · Amputations

Federal OSHA recorded a severe workplace injury at Chemtex, LLC, 143 Garrett Way NW, MILLEDGEVILLE, GEORGIA 31061 on — Amputations, affecting the finger(s), fingernail(s), unspecified.

Watch Chemtex, LLC — free Get an email when a new federal OSHA severe-injury report for Chemtex, LLC is published. One employer, no account, unsubscribe in one click.

A temporary employee was trying to help pull a jammed pad through a pad cutter. The cut button was pressed while the employee's thumb was in the path of the blade, which partially amputated the thumb.

Amputation Finger(s), fingernail(s), unspecified Metal, woodworking, and special material machinery, unspecified

Chemtex, LLC

An employee was pushing extra material through a bonder machine when their right hand contacted the bonder, resulting in the amputation of four fingers at the palm level.

View Chemtex, LLC's full OSHA safety record →

DGS Import, LLC

An employee was changing a saw blade when the saw machine activated. The employee's left ring and little fingers were amputated.

Millennium Mat Company

An employee was clearing a jam from the label cutting machine when their left middle finger was partially amputated.

Bauer Foundation Corp.

Two employees were repairing the hydraulic engagement pins on a rented front-end wheel loader. The machine controls were activated to move the attachment pins and an employee's finger was caught between the pins and the bushings. Their right index finger was partially amputated.

Guggisberg Cheese, Inc.

An employee was cleaning the conveyor on a piece of equipment when they slipped and their right hand was pulled into the chain sprocket. The employee's fifth fingertip was amputated.

Alsco Inc.

An employee was throwing blankets onto a blanket folding and stacking machine. A blanket got stuck in the machine and she attempted to remove it when the machine contacted her right little finger, resulting in a fingertip amputation.

Alpha ProTech Engineered Products, Inc

An employee was working from a ladder and adjusting a spreader guide roller with a T-handle Allen wrench. The employee came into contact with an electrical junction box/wires, was shocked, and fell off the ladder to the concrete floor. He suffered a broken right-side rib, a puncture in the right lung, and an electrical shock burn to the right palm.

Freudenberg Texbond LP

On January 3, 2025, at approximately 11:35 AM, an employee was inspecting and changing spin pumps on a line. He was using an impact gun to remove the bolts when the pressure sprayed hot polymer on his head, face, and arms resulting in burns. The employee was hospitalized.

Schwartz Manufacturing Company

An employee was doing quality control work to get the right thickness of the material. She contacted a component on a mill and sustained the amputation of four fingers on her right hand.

Suominen US Holdings, Inc.

An employee was servicing the belt on a fan when their right ring finger became caught between the belt and pulley. They sustained amputation of the fingertip. The machine was locked out at the time.

Freudenberg Texbond LP

An employee was clearing a clog on a drum shredder. The drum, still windmilling, amputated four fingers on the employee's left hand.

GS II Building Products, Inc.

An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.

US Battery Manufacturing Company, Inc

A casting machine jammed. An employee's hand was caught in the machine, where a belt line caught and amputated the tip of his finger.

Alfa Insurance

During a workshop meeting in a hotel, an employee heard a drilling noise, so he walked outside to see what it was. An explosion occurred (possible gas line) and his face, ear, and hair were burned. He also fell and sustained a pelvic fracture.

EMORY UNIVERSITY HOSPITAL

An employee slipped on condensation on a walkway in a parking garage. She fell and suffered a closed fracture to the neck of the left femur.

Bull Moose Tube

An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.