Struck by dislodged flying object, particle · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at Georgia Pacific Corporation, 1 G P Lane, GURDON, ARKANSAS 71743
on — Fractures, affecting the tooth (teeth).
Final narrative
An employee was removing a 6' x 6' cover from a log chipper using a hoist. The chipper disc contacted the cover which then dislodged from the hoist and struck the employee, resulting in lacerations to the head, neck and face and broken teeth.
An employee was rearranging unit stacks inside a trailer. He stepped onto one unit (5.5 feet tall) to push the unit behind it. The employee fell between the two units onto the floor of the trailer, resulting in five broken ribs on the left side and a punctured left lung.
An employee was clearing a fault on her machine when she slipped on preprint corrugated sheets lying on the floor and fell to the concrete floor. She sustained a fractured right hip and a bruised right wrist.
An employee was repairing a sight glass on a water holding tank and noticed a leaking pipe that needed repair. He stepped onto a 3-inch pipe and his wrench fell, causing him to lose balance. The employee fell onto a mixer motor and landed on the floor. The employee sustained a fractured left wrist, fractured left clavicle, and five fractured ribs.
An employee was helping to remove a tote filled with ink when the tote contacted his left hand and pinched his finger between it and a metal frame, amputating his fingertip.
An employee was fixing a spacer on a stack of 2 x 10's when a few of the 2 x 10's fell on his left leg, breaking his tibia and fibula. He was hospitalized and had surgery.
An employee was tossing a damaged toilet into a compactor. The toilet bounced off the compactor and lacerated the employee's right wrist, cutting an artery and tendon.
An employee was operating a hydraulic jack to bend a frame when the jack came loose and struck the employee. They were hospitalized for a spleen injury.
A truck had been towed into the shop with a flat tire and a blown airbag. An employee checked the tire for damage and was airing the tire. The employee was installing the valve core when the bead slipped off the rim. Air escaped, and the aluminum wheel struck the employee's head and face. The employee became unresponsive and was bleeding.
On December 14, 2023, at 8:40 p.m., three employees were inspecting milling machines for startup. A few of the sleeves on the mill drum needed to be changed out. The injured employee was trying to input a sleeve on the mill drum using a hammer. The hammer hit the edge of the drum, which caused a metal piece to splinter off and strike the employee's cheek just below the left eye. The metal splinter embedded in the back of their eye socket, resulting in pain, swelling, and bleeding that required hospitalization.
An employee was pushing a line of carts into a vestibule when the door cable snapped and struck his right ankle. The employee suffered a fracture that required surgery and hospitalization.
More severe injuries in this industry (NAICS 321113)
An employee was repairing a photo eye on the infeed roll case when they dropped a tool. The employee went to grab the tool and his fingers contacted the chain and sprocket of the infeed roll case. His fingers were pulled into the pinch point and the fingertips were crushed, resulting in amputation of one fingertip.
An employee was troubleshooting dispersing equipment. A belt and pulley system was energized, and the moving belt caught the employee's right ring finger. He suffered a partial amputation at the first knuckle, below the nail.
An employee was cleaning the photo eye sensors of a piece of equipment between the saw that cuts lumber into lengths and boards. The employee stepped on a metal grate that gave way and fell 8-10 feet. The employee was able to remove himself from the conveyor. His tibia was fractured just below the knee.
While refilling a lubricant tank, an employee observed that a pump was not operating correctly. While troubleshooting the issue, the employee reached toward the back of the pump to check for proper airflow. Their left index finger contacted moving components in the pump's piston mechanism, resulting in partial amputation of the fingertip.
An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.
On October 25, 2025, an employee was stringing up a new reel of tire tread on a machine. The employee pulled a 6-inch tail and proceeded to spool up the liner. As the machine was jogged to begin the liner wrapping process, the liner caught the employee's glove and pulled their right arm into the liner, causing a fracture to the arm.
An employee was doing a cable change on top of an electric overhead traveling (EOT) crane. They were positioned between the cable drum and the drive shaft. While rotating the cable drum, the employee reached for the new cable that was to be installed. The grease fitting on the drive shaft caught their fall harness and pulled them underneath the drive shaft. The employee was pinned between the drive shaft and two pieces of angle steel, resulting in a fracture to their left hip.
On October 5, 2025, an employee was pulling a pressure washer hose when it it disconnected from the cooker. The employee was struck by jets of high-pressure water, resulting in lacerations to their left thigh requiring surgery. The employee was hospitalized.