Indirect exposure to electricity, greater than 220 volts · Third or fourth degree electrical burns
At a glance
Federal OSHA recorded a severe workplace injury
at A-Z Prestige, LLC, 3464 Old Dixie Hwy., DALTON, GEORGIA 30721
on — Third or fourth degree electrical burns, affecting the foot (feet), unspecified.
Final narrative
An employee was using an aluminum concrete float to screed recently poured concrete on a parking lot. While moving the float pole, the employee came into contact with an overhead power line. The employee suffered third-degree burns on both feet.
A crew was working near an electrical pole. A co-worker was using a front-loader to grade a slope when the loader slid into a guy-wire and became tangled and stuck. The injured employee used a handheld grinder to cut the wire a few feet from the ground. The lower part of the wire fell to the ground, but the upper part of the wire fell toward the pole and contacted an energized part before the end landed in nearby bushes. The employee attempted to shake the bush to free the wire so it could fall back toward the pole. The wire popped up and contacted his hands, resulting in electrical entry burns to both hands and exit burns on both feet.
On November 18, 2023, two employees were using a 2x4 to lift a power line. The boom lift they were operating made contact with power lines and both employees sustained electrical shock injuries.
An employee was part of a crew that was servicing a power line. The employee was in a bucket truck when he contacted the 7,200-volt power line. The electricity entered through one hand and exited the other, causing several electrical burns. The employee was not wearing proper personal protective equipment at the time.
An employee was helping a crew set up a 45-foot pole between two other poles. It was being set up between two energized lines and the pole made contact with the A-phase. The employee was electrocuted and lost consciousness. The electricity also caused an entry wound in their left forearm and an exit wound in their left foot.
An employee was handling a 45-foot long rebar for installation on the third floor of a building at a 30-foot elevation. The rebar came into close proximity of a powerline situated 13 feet off the building. The employee sustained electrical burns to his hands from electric discharge, requiring hospitalization.
More severe injuries in this industry (NAICS 238110)
An employee was readjusting a safety hook to remove hardware from gang forms when his feet slipped. He fell to the ground, resulting in a broken left arm and wrist.
An employee was changing a boom pipe delivery system on a concrete pump truck. He tripped and fell from an elevated level to the ground, resulting in multiple leg fractures.
An employee was reading numbers off a belt that feeds a plant. He reached his hand up and the belt caught his finger, resulting in a finger amputation.
An employee was guiding the pouring end of a concrete pump truck's boom while standing on top of 4-foot wall forms. The boom contacted power lines and the employee was shocked. The employee sustained third-degree burns on the entry and exit path of the electricity, and also sustained first- and second-degree burns to their torso and legs.
An employee was holding a form board on a section of pavement. A skid steer backed into the employee's ankle, breaking it. The employee was hospitalized.
An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.
During a workshop meeting in a hotel, an employee heard a drilling noise, so he walked outside to see what it was. An explosion occurred (possible gas line) and his face, ear, and hair were burned. He also fell and sustained a pelvic fracture.
An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.