Quality System Services, Inc.

Struck against moving part of machinery or equipment · Cuts, lacerations

Federal OSHA recorded a severe workplace injury at Quality System Services, Inc., 308 W. Railroad St., LONG BEACH, MISSISSIPPI 39560 on — Cuts, lacerations, affecting the forearm(s).

An employee was operating a grinder when its wheel lacerated the employee's left forearm.

Hospitalized Forearm(s) Grinders, abraders

Leidy's LLC

An employee was operating a band saw when his right little fingertip was amputated.

Swift Beef Company

An employee was operating a strip saw. As the employee shut off the saw, their right index and middle fingertips were amputated by the blade before it came to a complete stop.

Kitchen Tune-Up

An employee was using a table saw to cut a piece of wood for wall framing. The wood jumped, causing the employee's hand to move toward the saw, amputating their left index finger and causing a laceration on their hand.

BBCJ LUMBER LLC

An employee was operating a trim saw. While trying to free a jammed board she had just cut, she came into contact with the running saw blade, which amputated her right thumb.

Appalachian Wood Floors, Inc.

An employee was using a shaper to cut wood when their right hand contacted the blade, resulting in a partial amputation to the right ring finger.

NATIONAL MILL MAINTENANCE, LLC

An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.

Elkhorn Mechanical and Combustion

An employee was climbing a ladder to inspect a vent in a restaurant dining area. The ladder slid out on the floor and the employee fell approximately 12 feet onto the ladder and the floor. He was hospitalized with a dislocated shoulder and a back injury.

Crown Lift Trucks

An employee was operating a lift truck when it struck a stationary lift truck. His left thumb was pinched between the two lift trucks, resulting in a partial amputation.

Spellman High Voltage Electronics Corporation - Valhalla

An employee was disassembling a pressurized unit using a driver drill. When the unit was disassembled, it caused a kickback from the tube head, causing the drill to strike the employee's left forearm. They sustained a diaphyseal fracture to their left radius and ulna, which required surgery.

Ring Power Corporation

After repairing a piece of industrial equipment, an employee had brake-cleaning liquid on his gloves. A lighter ignited the liquid, and the employee's hands were severely burned.

Howard Industries Inc.

An employee was checking a pole-type transformer tank for leaks. A hydraulic clamping device was lowered onto his right thumb and crushed it against the sharp edge of the bottom of the tank. He suffered a partial transphalangeal amputation to the thumb.

Hobby Lobby Stores, Inc.

The injured employee was standing behind a table. She jumped out to scare another employee, but tripped and fell on the tile floor, injuring her right ankle/foot. She was hospitalized with a dislocated ankle that required surgery.

Owl's Head Alloys West Point

An employee was going into a trailer to mark product for shipment and the trailer pulled away from the dock. The employee fell out of the trailer, contacted the dock plate, and then fell to the ground. The employee was hospitalized with a punctured lung, fractured ribs, and contusions.

Ingalls Shipbuilding

An employee was hooking up bundled tie-downs with a chain. While he was holding a hook, the other hook was unlocked. This caused the employee's hook to slide down and pinch his right index finger between the chain and the shackle. He suffered an amputation to the fingertip (without bone loss), as well as an open fracture.

Heavy Equipment Movers and Installation, LLC

An employee was operating a gas tugger to lift metal sheeting. His left hand was pulled into the pulley, which crushed his left thumb, resulting in avulsions and other tissue damage. He was hospitalized and required surgery.