Compressed or pinched by shifting objects or equipment · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at Precision Group, 315 North Park Drive, SAN ANTONIO, TEXAS 78216
on — Amputations, affecting the fingertip(s).
Watch Precision Group — freeGet an email when a new federal OSHA severe-injury report for Precision Group is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee was doing a final inspection of a metal plastic injection mold. The mold smashed his left thumb. He underwent a medical amputation to the top of the thumb at the nail bed, with bone loss.
An employee was operating a forklift and unloading a truck. After the truck was unloaded, the employee got off the forklift and proceeded to adjust the dock plate with a hook tool. The dock plate slipped and the employee went to adjust the plate with their hand when their left middle finger got caught. Their finger was amputated above the first joint.
An employee was rotating a carbide granulator blade when his finger was caught between the blade and a stationary part of the machine. The employee's right middle finger was partially amputated and they suffered an avulsion to the right ring fingertip.
An employee was using a CNC metal lathe machine in manual mode to check that the thread blocking tool made contact with the jaws. As the employee was manually spinning the spindle, his index fingertip was crushed between the spindle's jaws and the grooving insert, resulting in a fingertip amputation.
During a material handling operation, an employee's fingertip was caught under an air conditioning unit as the unit was lowered onto a cart. The employee's fingertip was amputated.
An employee was removing a bolt from a tractor hub when their right index finger was caught between the hub and the frame. The employee's fingertip was crushed and the employee was hospitalized.
More severe injuries in this industry (NAICS 333511)
An employee was operating an overmolding injection machine. His left hand was crushed when the hydraulic plates came together to complete the overmold process. The employee was hospitalized with a fractured left ring finger and abrasions on both sides of his hand.
On April 4, 2025, an employee was assembling a cooker and was positioning a shaft inside the shell. The shaft was lifted up on each end. When the weight is off the shell, cranes move north or south to position the cooker inside the shell. The cooker shaft suddenly moved and his right middle finger was caught between the cooker shell and a gauge block. The finger was amputated to the bottom of the fingernail.
An employee was using a floor-mounted vertical sander to deburr a part. The part got caught between the guard and the sander. The employee's hand was pulled in and the sander crushed the employee's fingers.
An employee was operating a wax injection die. The die's metal lid (which weighed about 125 pounds) fell on his hand. He suffered crush injuries to the index and middle fingers that required surgery.
On June 27, 2024, an employee was assembling a completed mold top weighing 1,261 pounds. The hook from the hoist was under tension. She went to adjust the hook and it moved, catching her left thumb against the mold top. She sustained an amputation to the tip of the thumb.
After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.
An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.
An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.