Direct exposure to electricity, unspecified · Electrocutions, electric shocks
At a glance
Federal OSHA recorded a severe workplace injury
at A. A. Will Corporation, 87-101 Cambridge Park Drive, CAMBRIDGE, MASSACHUSETTS 02140
on — Electrocutions, electric shocks, affecting the bODY SYSTEMS.
Final narrative
An employee contacted a live power connection while chipping a duct bank to install new building water service. The employee was shocked.
An employee was installing a 15-amp breaker in an electrical panel when a 12-gauge ground wire touched the positive busbar of the panel, resulting in an arc flash. The employee sustained a second-degree burn to their left hand.
An employee was repairing an HVAC system in the drop tile ceiling of a conference room when they were shocked, causing them to fall from the ladder. The employee sustained burns to their right middle and ring fingers.
An employee was replacing a contactor inside an electrical panel attached directly to a press. The press itself was receiving power from another main panel. After replacing the contactor, the employee flipped the switch and an arc flash occurred, burning the employee's elbow, bicep, and neck.
An employee was attempting to switch a medium-voltage primary cable and install a 200-amp fuse barrel. The employee contacted the bottom of the switch gear cradle for the fuse barrel, causing an arc blast. The electricity entered the employee s left hand and exited his big toes, resulting in electric shock and burns to the left hand, arm, shoulder, and both feet. The employee was hospitalized.
On December 6, 2023, an employee of Duke Energy was working on a single-phase 120-/240-volt parallel service re-tap when a secondary flash occurred in an underground service. The employee suffered a second-degree burn to the face and was hospitalized.
More severe injuries in this industry (NAICS 238910)
An employee was directing trucks as they entered and left a highway work zone. A vehicle struck them, resulting in multiple fractures and other injuries. The employee was hospitalized.
An employee was assisting the crew with patching and restoring a roadway after the installation of a sewer line. He was helping place and level the blacktop/backfill material over the trench area to bring the road surface back to proper grade. The employee was walking between a forward-moving dump truck and a dirt pile when his right foot was run over by the truck s wheel, causing him to fall. The employee sustained injury to his foot.
An employee was operating a skid steer with a bucket attachment at a demolition site. While driving it to the rear of the property to park it, the employee came into contact with a live electrical transformer unit that was located outside of the facility. The employee sustained electrical burns on his hands extending up to his elbows and a fractured ankle.
An employee was installing a door on a semi-trailer. They were using a forklift to lift the door to the height of the trailer when the door became jammed between the forklift mast and the hinge on the trailer. When the employee went to dislodge the door from the mast, the door fell and crushed their foot. Their big toe was amputated. The employee was hospitalized and their big toe was surgically reattached. The employee's foot and other toes also required surgery.
An employee fell while exiting a trailer. The employee landed on their left side on the pavement, suffering multiple broken ribs on the left side. The employee was hospitalized.
Two employees were setting up a mandrel in the spindle of a machine. The mandrel was side-shifted while an employee's hand was on the mast of a powered industrial truck. The employee suffered crushing injuries that resulted in amputations to the middle and ring fingertips.
An employee had been loading a double deck press. The employee saw a mold had been sent in with the C-hook still attached on the belly bar. As he went to remove the hook from the mold, his right thumb got caught on the C-hook. The employee's thumb was partially amputated.
An employee was operating a roller and paving a small pathway next to a pavilion. The ground was on a slight pitch, causing him to reach up toward the roll cage to stabilize himself. His right fifth finger was pinched between the roll cage and the rafter of the pavilion. The employee sustained a partial degloving injury with partial traumatic amputation.
An employee was delivering home heating fuel when bees came from the ground and stung the employee's face, neck, torso, and hands. The employee proceeded to shut off the oil flow before losing consciousness. They were hospitalized due to an anaphylactic reaction.