105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Electrical Services, Inc

Ran off driving surface, nonroadway · Fractures

Federal OSHA recorded a severe workplace injury at Electrical Services, Inc, 1102 John Glenn Boulevard, TITUSVILLE, FLORIDA 32780 on — Fractures, affecting the hip(s).

An employee was moving a scissor lift out of a building. As the lift moved down a ramp, it went off the side. The employee struck the concrete ground and his left hip was broken.

Hospitalized Hip(s) Aerial lifts, scissor lifts-except truck-mounted

Double D Express, Inc.

On November 17, 2023, an employee was unloading a trailer using a forklift when the truck drove away, causing the employee and the forklift to drop to the ground. The employee suffered back injuries that required hospitalization.

Tropicana Manufacturing Company, Inc.

An employee was driving a golf cart when its left leaf spring cracked, causing the cart to abruptly turn left into a nearby ditch. The employee suffered three fractures in his right leg below the knee, as well as severe lacerations on his head and forehead.

Raymour & Flanigan

An employee was operating a forklift to unload a truck when the truck pulled away. The forklift and the employee fell approximately 3.5 feet. The employee sustained fractures to the arm and neck as well as a head contusion.

SG Metal & Glass LLC

An employee was moving a scissor lift onto a loading dock ramp when the lift fell over the side of the ramp with the employee in it. They sustained rib fractures.

Core-Mark International, Inc.

An employee was operating a forklift and unloading a trailer when the trailer pulled away from the dock. The forklift rolled backward and fell out of the trailer. The employee sustained head trauma and a back injury.

Smart Building Technologies - A Fidelity Company

An employee was troubleshooting the control setup for a variable air volume box above a ceiling. The employee's hand came into contact with an exposed, energized 277-volt wire that had loosened from its terminal on the box's assembly. He was shocked and fell off a ladder. His left hand passed across the ceiling grid and was lacerated. He also suffered an electrical burn to the right hand and was hospitalized.

Abbott Electric Inc

An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.

Mintcrest Corp

An employee was standing on an A-frame ladder approximately 6 feet above the floor while he attached a suspended light fixture to the ceiling. The employee lost balance, and fell to the tiled floor below, sustaining blunt force trauma to his head.

Cupertino Electric, Inc.

An employee was inspecting the overhead area of a single-person lift and repositioning the lift through a double doorway. As they were transitioning through the doorway, they were caught between the doorframe and the vertical mast of the lift. The employee was hospitalized with injuries to the nose, left maxillary sinus, left orbital bone, and left jaw, with fractures at the maxillary sinus area.

Swedberg Electric, LLC

The injured employee was performing routine maintenance on a fan belt/pulley. The injured employee and another person were moving the pulley back and forth manually to find a bearing issue. The injured employee's left ring finger got caught between the belt and the pulley wheel, resulting in a soft tissue amputation.

DRIFTWOOD NURSERY & LANDSCAPING, INC

An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.

Hobby Lobby Stores, Inc.

An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.

Envelope Seal Insulation, Inc

An employee was inspecting a generator whose radiator was leaking. He slipped, and a fan blade in the generator amputated his thumb and index finger.

Sugar Cane Growers Cooperative of Florida

An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.

Air-flo/Erwood Heating & Air Conditioning

An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.