Struck against moving part of machinery or equipment · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at AMERICAN BOA, INCORPORATED, 1485 REDI RD, CUMMING, GEORGIA 30040
on — Amputations, affecting the finger(s), fingernail(s), unspecified.
Watch American BOA, Incorporated — freeGet an email when a new federal OSHA severe-injury report for American BOA, Incorporated is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee was using a bandsaw to cut tubes that were clamped in place. The employee heard one of the tubes move and, as she turned around to see what was going on with the saw, her right index finger went between the blade and the partially cut tubes, resulting in a partial amputation.
An employee was operating a strip saw. As the employee shut off the saw, their right index and middle fingertips were amputated by the blade before it came to a complete stop.
An employee was using a table saw to cut a piece of wood for wall framing. The wood jumped, causing the employee's hand to move toward the saw, amputating their left index finger and causing a laceration on their hand.
An employee was operating a trim saw. While trying to free a jammed board she had just cut, she came into contact with the running saw blade, which amputated her right thumb.
An employee was troubleshooting a shell core machine that had failed to raise the sand hopper into place for core making. The employee went to manipulate a switch and the machine cycled. The employee s left middle fingertip was caught between the roller-ball switch and the roller-ball switch target, resulting in a laceration that required surgical amputation to part of the distal phalanx.
On August 18, 2025, at approximately 7:40 AM, an employee utilized a pocket knife to cut banding on a new bundle of rod material. The knife blade bent during use. The employee was working to straighten the blade on a hard surface when the knife slipped, causing a lacerating their right wrist/forearm. The employee was hospitalized.
An employee was manually pulling drive belts to rotate a machine that needed repair. The employee's right index finger was pinched between a rubber drive belt and a pulley, causing an amputation to the fingertip.
At about 9:15 a.m. on May 14, 2025, an employee was using a bending press to bend metal into a U shape. The press caused an amputation to the employee's left middle finger.
An employee was running a test pipe for 12 feet and went to pull the pipe out of a roll grooving tool. As he was doing this, the tool's control pedal actuated, causing the tool to rotate. The employee's glove became caught and was pulled into the rollset, amputating about half an inch of his index finger.
An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.
During a workshop meeting in a hotel, an employee heard a drilling noise, so he walked outside to see what it was. An explosion occurred (possible gas line) and his face, ear, and hair were burned. He also fell and sustained a pelvic fracture.
An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.