105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

MPW Industrial Water Services, LLC

Direct exposure to electricity, unspecified · Electrical burns, unspecified

Federal OSHA recorded a severe workplace injury at MPW Industrial Water Services, LLC, PBF Energy, Delaware City Refinery (DCRC), DELAWARE CITY, DELAWARE 19706 on — Electrical burns, unspecified, affecting the multiple body parts, n.e.c..

An employee was remotely monitoring equipment when he noticed and reported an equipment issue that indicated a motor was not performing within parameters. He and another employee went to check the equipment in the field when an arc flash occurred. Both employees sustained burns to both hands and to the head. One employee was hospitalized.

Hospitalized Multiple body parts, n.e.c. Nonclassifiable

Bob Woodall Air Care Systems, Inc.

An employee was installing a 15-amp breaker in an electrical panel when a 12-gauge ground wire touched the positive busbar of the panel, resulting in an arc flash. The employee sustained a second-degree burn to their left hand.

Amentum Spaceport LLC

An employee was repairing an HVAC system in the drop tile ceiling of a conference room when they were shocked, causing them to fall from the ladder. The employee sustained burns to their right middle and ring fingers.

Marsh Bellofram Corporation

An employee was replacing a contactor inside an electrical panel attached directly to a press. The press itself was receiving power from another main panel. After replacing the contactor, the employee flipped the switch and an arc flash occurred, burning the employee's elbow, bicep, and neck.

Heart Utilities of Jacksonville, Inc.

An employee was attempting to switch a medium-voltage primary cable and install a 200-amp fuse barrel. The employee contacted the bottom of the switch gear cradle for the fuse barrel, causing an arc blast. The electricity entered the employee s left hand and exited his big toes, resulting in electric shock and burns to the left hand, arm, shoulder, and both feet. The employee was hospitalized.

Duke Energy Florida, LLC

On December 6, 2023, an employee of Duke Energy was working on a single-phase 120-/240-volt parallel service re-tap when a secondary flash occurred in an underground service. The employee suffered a second-degree burn to the face and was hospitalized.

Reworld Lee, Inc.

An employee was performing maintenance on a hopper. The employee's hand was caught in a cylinder pivot point area when the pneumatic cylinder released trapped air. The cylinder crushed the employee's left little finger, causing the partial amputation of the fingertip.

WM - Northwest Transfer Station

An employee was opening a door to a semi trailer at the facility and his hand was caught between the door and another parked semi. The employee's left index finger was fractured and thumb muscles were injured. The employee was hospitalized and required surgery.

QSI

An employee was removing residual meat particles from the sprocket of the crossover conveyor belt in the packing area. While doing so, the conveyor started and his fingers were caught between the metal framework and the belt, resulting in amputations to the middle and ring fingers on the left hand as well as skin damage to the right hand.

Alpha Recycling Hwy 80, Inc

An employee was unloading vehicles. While unloading a van, the brakes failed and the vehicle rolled off the car hauler and ran over the employee. The employee was hospitalized for a lower left leg fracture.

Republic Services

An employee was servicing the compactor. They were reconnecting the turnbuckle on a receiver box when the turnbuckle slipped and fell, crushing the employee's left middle fingertip. The employee was hospitalized for surgery.

Greggo & Ferrara, Inc.

A flagger was directing traffic flow in a highway work zone. They were standing approximately 1.5 feet behind the shoulder's demarcating line, next to and slightly behind a traffic drum. As they were directing traffic into and out of the driveway of a parking lot, a car attempted to get around a truck and struck the traffic drum, which subsequently struck the employee, who was thrown 15 feet and landed on top of concrete aggregate. The employee suffered pelvic and rib fractures, T10 and L3 vertebra fractures, and internal bleeding.

GREGGO AND FERRARA, INC.

An employee was troubleshooting a power washer in the field. Because there might have been water in its fuel, he brought it back to the shop and drained about a gallon of fuel from the tank into a plastic container. Some of the fuel spilled onto the floor and ignited. The employee was stomping out the fire when he lost his balance and tripped into a stool, which caused the plastic container to spill more fuel onto the fire. The employee's pants and shirt caught on fire, and he fell, abrading his knee while trying to get through the flames. As well as the knee abrasion, he suffered burns to the left leg and left lower quadrant of the torso. He was hospitalized.

CHRISTIANA CARE HEALTH SERVICES, INC.

An employee was backing up a tram (towing powered industrial equipment) to connect it to a trash bin. The employee's left forearm/wrist was caught and crushed between the tram and the bin. The employee was hospitalized.

HomeGoods ,LLC-Newark, DE

An employee went to lift a carton and tripped on a different carton that was on the floor. She fell on the floor in the backroom and sustained a fractured right hip, and abrasions to her arm and knee. The employee was hospitalized and required surgery.

NKS Distributors

An employee was conducting a delivery of beverage products and began having cramps due to dehydration. The employee was hospitalized.