An employee was working on the well head when the service brake broke causing the elevator to fall on their hands. The employee sustained bilateral hand fractures and was hospitalized.
HospitalizedHand(s), unspecifiedOil drilling rigs and machinery
An employee was changing mud cups in the hopper cylinders of a concrete pump truck. The cylinders moved and three of the employees fingers were amputated.
An employee was standing on the rig floor next to a polishing unit. His hand was placed on the polishing unit when the pump was lowered, resulting in amputation of their right thumb, ring, and middle fingertips.
An employee was using air to blow out the air wash to the blender and grinder station. As the employee reached to verify that the air wash was clean, the unit pinched and amputated their fingertip.
An employee was retrieving a lost drill pipe with a lifting bail when their left thumb got pinched between the table and handle of the lifting bail while trying to re-thread the pipe to lift it out. The employee suffered an amputation to the left thumb.
An employee was removing a core chuck from a stationary roll when their right ring finger was pinched between the chuck and the roll. The employee's fingertip was amputated.
More severe injuries in this industry (NAICS 213111)
An employee was stepping down off a 6-inch containment platform to finish loading his truck, when his right ankle rolled. The employee sustained a fractured tibia and fibula at the right ankle and required surgery.
A service crew was pulling a pump and motor from a well. After breaking a joint of pipe loose from another joint, an employee grabbed the chain tongs to prevent the pipe from spinning in the well, so the crew could continue taking it apart. The bolt that attaches the chain to the handle of the chain tongs broke, causing the chain to swing around and strike the employee's lower right leg. The chain severely punctured his leg and fractured his tibia.
An employee arrived on location and loaded a blow-out-preventer (BOP) on a 1-ton flatbed truck. While standing on the flatbed securing the the BOP, the employee stepped into a void/hole on the flatbed surface. This caused him to lose balance and fall off the truck bed with his leg still caught in the hole. As a result, he sustained fractures to his left leg.
An employee was rigging up a location. He was using an Allen wrench to free up rotation and start the drawworks engine manually. The engine rotated and his left little finger became caught between the Allen wrench and the engine. The employee sustained an amputation to his little finger and fractures to his wrist.
An employee was conducting routine maintenance on a mixer. New lid pins had been installed, and the employee was rotating by hand to ensure they had been installed correctly. The employee's left middle finger was caught between the lid and top of a pin. The momentum from the mixer continued, causing a crushing injury to the finger. The employee underwent a medical amputation from the top knuckle to the tip of the finger.
An employee was climbing down a 15-foot multipurpose ladder. The employee fell about 8 feet, landing on the concrete floor and the ladder itself. The employee suffered several injuries, all on the right side: broken ribs, a broken sternum, a broken temporal bone, broken shoulder, multiple fractures to the cheekbone, and a brain bleed.
An employee was rolling up the landing gear on his trailer when the handle began to unwind and struck his face, fracturing his jaw. The employee was hospitalized and required surgery.