Federal OSHA recorded a severe workplace injury
at B. BRAUN MEDICAL, INC., 901 MARCON BOULEVARD, ALLENTOWN, PENNSYLVANIA 18109
on — Fractures, affecting the hip(s).
Final narrative
An employee was at the time clock area when they lost balance and fell to the floor, resulting in a hip fracture.
An employee was checking for an air leak on an injection molding machine. The machine actuated, causing amputation to the employee's left index finger.
On January 9, 2021, an employee was buffing a floor with an orbital buffer. The cord wrapped around his ankle and he fell backward, fracturing his skull.
An employee was pulling on a bale of corrugated cardboard boxes that were on a conveyor. The straps on the bale failed and the employee fell to the floor. The employee was hospitalized and required surgery for a fractured femur and/or hip.
On December 27, 2023, an employee was delivering mail to an apartment complex when their knee gave out and they fell to the ground. The employee was hospitalized with a left tibia fracture.
An employee was walking to the inventory cage when her ankle gave out and she fell to the floor. The employee sustained a femur fracture and was hospitalized.
An employee was dislodging a pallet that was stuck when boxes of product fell onto them, causing them to fall to the ground. The employee suffered a fractured femur.
An employee was operating a standup forklift in the warehouse. The forklift struck racking, causing the employee to lose their balance. Their left foot became caught between the forklift and the racking and was fractured.
An employee was servicing a circuit board on a portable X-ray unit when a battery cable touched part of the board, causing electrical burns to two fingers on his right hand.
A plumber was unclogging a sink in an employee's work area when the employee suffered an allergic reaction and an asthma attack from the liquid drain-cleaning chemicals.
The injured employee was putting away materials on the warehouse floor as a co-worker was pushing a pallet onto a nearby shelf. The pallet knocked another pallet forward, causing it to fall onto the injured employee's shoulders. The employee suffered fractures in their right and left knees and ankles.
An employee was walking into the motor control center (MCC) room when his right ring finger was caught in the hinge of a doorway. He sustained an open phalanx fracture, which resulted in a partial amputation above the first knuckle.
An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.
An employee was pulling down a broken skid with a forklift. When the employee backed up the forklift to get the forks out of the skid he pulled down, he contacted the forks of another parked forklift, fracturing both of his legs. He was hospitalized.
An employee was carrying cups back to the kitchen when her foot got caught on a cart and she fell face-first. During the fall, a piece of glass from a cup cut the inside of her mouth, severing an artery. She also sustained a laceration on her lower lip. The employee was hospitalized.