International Steel & Counterweights LLC

Direct exposure to electricity, unspecified · Electrical burns, unspecified

Federal OSHA recorded a severe workplace injury at International Steel & Counterweights LLC, 140 North West Avenue, YOUNGSTOWN, OHIO 44502 on — Electrical burns, unspecified, affecting the hand(s), unspecified.

On 7/13/2023, an employee was repairing a wiring assembly on a crane. While re-energizing the crane, the wires shorted out in a different area. The employee was hospitalized for electrical burns to their right hand as well as dust inhalation.

Hospitalized Hand(s), unspecified Cranes, unspecified

International Steel & Counterweights LLC

The injured employee and a co-worker were carrying an elevator weight. The co-worker let go of their half and the weight fell onto the employee's right hand, resulting in a partial amputation of the right index finger that required hospitalization.

View International Steel & Counterweights LLC's full OSHA safety record →

Bob Woodall Air Care Systems, Inc.

An employee was installing a 15-amp breaker in an electrical panel when a 12-gauge ground wire touched the positive busbar of the panel, resulting in an arc flash. The employee sustained a second-degree burn to their left hand.

Amentum Spaceport LLC

An employee was repairing an HVAC system in the drop tile ceiling of a conference room when they were shocked, causing them to fall from the ladder. The employee sustained burns to their right middle and ring fingers.

Marsh Bellofram Corporation

An employee was replacing a contactor inside an electrical panel attached directly to a press. The press itself was receiving power from another main panel. After replacing the contactor, the employee flipped the switch and an arc flash occurred, burning the employee's elbow, bicep, and neck.

Heart Utilities of Jacksonville, Inc.

An employee was attempting to switch a medium-voltage primary cable and install a 200-amp fuse barrel. The employee contacted the bottom of the switch gear cradle for the fuse barrel, causing an arc blast. The electricity entered the employee s left hand and exited his big toes, resulting in electric shock and burns to the left hand, arm, shoulder, and both feet. The employee was hospitalized.

Duke Energy Florida, LLC

On December 6, 2023, an employee of Duke Energy was working on a single-phase 120-/240-volt parallel service re-tap when a secondary flash occurred in an underground service. The employee suffered a second-degree burn to the face and was hospitalized.

Stanley Black & Decker, Inc.

An employee was pulling a steel parts handcart when its wheels caught on something and locked up. The cart fell backward. The cart handle struck the middle of the employee's right foot, breaking bones. The employee was hospitalized and required surgery.

Jamestown Metal Marine Sales, Inc.

An employee was cutting wood with a circular saw. The saw kicked back, and its blade cut three fingers on the employee's right hand, resulting in an amputation.

Architectural Metal Solutions, Inc.

An employee was installing a door from an A-frame ladder. He fell from the ladder, landed on his feet about 8 feet below, and suffered a broken tibia.

Spectrum Lighting, Inc.

An employee was leaving the building at the end of the day when she missed a step and fell, fracturing her right foot.

Metal Zinc, LLC

Two employees were running a CNC folder machine. The injured employee went to adjust the metal and the machine came down, crushing her forearms. Her left arm was fractured and both arms required stitches.

United States Postal Service

An employee was working to deliver mail to an apartment building. She was waiting for a customer to move, to obtain clearance to the mailboxes. The door swung inward and closed on her right little finger. The top half of her finger was surgically amputated.

Foundation Steel, LLC

An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.

GXO Logistics

On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.

Abbott Electric Inc

An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.

American Electric Power Company

An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.