Struck by swinging or slipping object, other than handheld, n.e.c. · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at Amite BioEnergy, LLC, 1763 Georgia Pacific Rd #2, GLOSTER, MISSISSIPPI 39638
on — Amputations, affecting the fingertip(s).
Final narrative
An employee was helping other employees remove a die cast when the die shifted. The injured employee went to catch it when the crane operator lowered the die onto the pallet and caught the employee's hand. They sustained an amputation of the little fingertip.
A maintenance technician was checking the tire pressure on a debarking drum tire. They then initiated the process of adding air into the tire to the specified pounds per square inch. Within seconds, the side wall of the tire ruptured and the maintenance technician sustained broken ribs and a punctured lung.
An employee was removing a piece of material from a machine after a malfunction when the air lock amputated their right middle and ring fingertips. The machine was not locked out/tagged out at the time.
A crew was pulling a 4-inch plastic gas pipe off a reel and straightening it for installation. The injured employee stepped up on the trailer to cut the last band holding the pipe in the coil on the reel. As he turned to step off the trailer, the end of the pipe rotated and sprung out of the cage surrounding the coil, striking the employee on the side of the head and knocking him off of the trailer into the roadway. The employee suffered head trauma that required hospitalization.
An employee and a co-worker were performing a pick inside a clear well. They rigged the skid pan that was full of broken concrete. When lifting, the load began to swing toward a wall. The employee tried to stop the skid pan from swinging and was struck by the pan, resulting in fractures to their left hip and wrist.
The employee had just completed refueling a lattice crane that was breaking up material and was winding the fuel hose back into the fuel truck when he was struck by the catwalk/stairs of the crane. The employee was hospitalized with a laceration to his backside, possible internal bleeding, and a broken hip.
An employee was fusing 10-inch black rubber utility pipes together using a pipe fusion machine and could not get the pipes to set correctly. The employee used a nylon strap attached to an excavator to lift one side of a pipe off a steel plate. As his hand was between two pipes, the pipes came back together, partially amputating two of his fingers.
An employee was lifting four bags of a lime blend weighing approximately 10,000 pounds using a crane. The load swung and pinned the employee against a structural I-beam, resulting in fractures to the hip and pelvis.
More severe injuries in this industry (NAICS 321219)
Two employees were investigating smoke originating from a screw at the base of a dry fuel silo. While they were in the ground-level hopper area, a dust explosion occurred. Both employees were burned. One suffered burns to both arms, the face, and the left side of the torso; the other was burned on the face and chest, as well as suffering circumferential burns to the arms.
At 8:00 a.m. on April 22, 2025, an employee was responding to a tracking fault on the bottom head of a six-head sander. While he was straightening the belt, his right hand was pulled in, wedged, and lacerated. He was hospitalized.
On January 20, 2025, an employee was walking between buildings when they slipped on ice and fell. The employee was hospitalized with fractures to their left tibia and fibula.
An employee was swapping motor leads to change the rotation on a river well pump motor when an arc flash occurred. The employee sustained second-degree burns to their hands and forearms.
An employee was checking a pole-type transformer tank for leaks. A hydraulic clamping device was lowered onto his right thumb and crushed it against the sharp edge of the bottom of the tank. He suffered a partial transphalangeal amputation to the thumb.
The injured employee was standing behind a table. She jumped out to scare another employee, but tripped and fell on the tile floor, injuring her right ankle/foot. She was hospitalized with a dislocated ankle that required surgery.
An employee was going into a trailer to mark product for shipment and the trailer pulled away from the dock. The employee fell out of the trailer, contacted the dock plate, and then fell to the ground. The employee was hospitalized with a punctured lung, fractured ribs, and contusions.
An employee was hooking up bundled tie-downs with a chain. While he was holding a hook, the other hook was unlocked. This caused the employee's hook to slide down and pinch his right index finger between the chain and the shackle. He suffered an amputation to the fingertip (without bone loss), as well as an open fracture.
An employee was operating a gas tugger to lift metal sheeting. His left hand was pulled into the pulley, which crushed his left thumb, resulting in avulsions and other tissue damage. He was hospitalized and required surgery.