105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Uniwell Laboratories

Caught in running equipment or machinery during maintenance, cleaning · Amputations

Federal OSHA recorded a severe workplace injury at Uniwell Laboratories, 14801 Sovereign Rd., FORT WORTH, TEXAS 76155 on — Amputations, affecting the fingertip(s).

An employee was cleaning a conveyor belt when their index finger got caught in the gears on the conveyor, resulting in a fingertip was amputation.

Amputation Fingertip(s) Conveyors-belt

DGS Import, LLC

An employee was changing a saw blade when the saw machine activated. The employee's left ring and little fingers were amputated.

Millennium Mat Company

An employee was clearing a jam from the label cutting machine when their left middle finger was partially amputated.

Bauer Foundation Corp.

Two employees were repairing the hydraulic engagement pins on a rented front-end wheel loader. The machine controls were activated to move the attachment pins and an employee's finger was caught between the pins and the bushings. Their right index finger was partially amputated.

Guggisberg Cheese, Inc.

An employee was cleaning the conveyor on a piece of equipment when they slipped and their right hand was pulled into the chain sprocket. The employee's fifth fingertip was amputated.

Alsco Inc.

An employee was throwing blankets onto a blanket folding and stacking machine. A blanket got stuck in the machine and she attempted to remove it when the machine contacted her right little finger, resulting in a fingertip amputation.

Takeda Pharmaceuticals U.S.A., Inc.

An employee fell while moving a water canister, resulting in fractures to four fingers on her right hand.

AbbVie Inc.

An employee was driving a boom lift (in the lowered position) in an exterior dock area. The lift s left wheels rolled onto base plates that covered a 3-foot-deep sump pit. The base plates failed, and one side of the lift dropped. The employee's left leg was caught under the lift basket, and he suffered a fracture to the lower leg including the ankle.

Bristol Myers Squibb

An employee was walking on the sidewalk. When they stepped off the curb, they fell to the ground, resulting in fractures to their tibia, fibula, and a metatarsal.

ARL Bio Pharma

An employee opened a flammables storage cabinet to get something out, smelled a chemical odor, and began to feel unwell and dizzy. She was hospitalized, having been exposed to formic acid from a leaking bottle at the bottom of the cabinet.

Leading Pharma LLC

The injured employee was cleaning a pre-mix blend from a high-speed mixer. Another employee working in the same room opened the pneumatic valve for the machine. The injured employee's right forearm was crushed in the mixer when the discharge valve closed. He was hospitalized.

T G Meat Center LLC

After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.

Professional Flooring Supply

An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.

EnviroSafe Demil LLC

An employee was inspecting flares processes. The employee received burns to the front side of the body, face and arm from the flares.

Inteplast Group

An employee was removing plastic material from a production line when the machine cycled and amputated his left index, ring, and little fingers.

Regency IHS of Fairwinds Halletsville, LLC

An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.