Vehicle or machinery fire · Heat (thermal) burns, unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Baytex Energy USA, 28 26'40.9"N 99 25'55.1"W, BIG WELLS, TEXAS 78830
on — Heat (thermal) burns, unspecified, affecting the multiple body parts, unspecified.
Final narrative
An employee was near a hybrid separator when it malfunctioned, resulting in a flash fire that burned the employee's upper body.
HospitalizedMultiple body parts, unspecifiedMineral sorters, separators, concentrators
An employee removed the spark plugs and was rotating an engine to evacuate condensate from the cylinders. An unknown source ignited the condensate and natural gas. The employee sustained burns to the back of his hands and upper leg area.
An employee was operating a front-end loader when a hydraulic line broke, causing the front-end loader to catch on fire. The employee jumped from the cab to the ground and sustained fractures to the T-6 vertebra and a heel.
An employee was moving two totes of turpentine. Noticing that one of them was leaking, he stopped his forklift and began to look for the leak. The forklift caught fire, and the employee suffered severe burns. He was hospitalized.
An employee was performing maintenance on a machine when part of an adjacent machine caught fire. The employee extinguished the fire and suffered smoke inhalation.
An employee was checking the inspection door to clean out any build up in the discharge chute. As the employee was heating the peanuts in the cooker to extract oil, he noticed embers and smoke in the discharge chute. The employee used a fire extinguisher to put out the embers and continued his work. As the employee opened the machine door next to the portal on the discharge chute, oxygen entered the chute and caused the peanuts to combust. A fireball shot out of the door and burned the employee's face, chest, and arms.
More severe injuries in this industry (NAICS 213112)
An employee had been cleaning the work area. While lifting a saw, the employee's index finger was lacerated by the saw blade. A tendon was cut and required surgery.
An employee was delivering home heating fuel when bees came from the ground and stung the employee's face, neck, torso, and hands. The employee proceeded to shut off the oil flow before losing consciousness. They were hospitalized due to an anaphylactic reaction.
An employee was using a torch to loosen a bolt on a water trailer. Natural gas was present in the water and it ignited, causing a fire. The employee sustained third-degree burns to their upper leg.
An employee had been conducting crane operations. The employee went to stop a piece of oil and gas equipment for tubular running from falling over to the ground. Their right hand was caught between a rolling ladder and the equipment, resulting in fractures to the index and middle fingers. They were hospitalized and the middle finger required surgery.
An employee was working to install a drive belt on a water pump. He was holding the belt on both sides of the pulley, working to route it over the top. As he pulled down with his right hand, the pulley rotated and the belt slid over it, pulling his left little finger between the pulley and the belt. He suffered an amputation to the fingertip as well as a fracture to the ring finger.
After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.
An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.
An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.