105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

TechnipFMC

Struck by discharged object or substance · Cuts, lacerations, punctures without injury to internal structures

Federal OSHA recorded a severe workplace injury at TechnipFMC, 12 Arentzen Boulevard, CHARLEROI, PENNSYLVANIA 15022 on — Cuts, lacerations, punctures without injury to internal structures, affecting the Hand(s), except finger(s).

An employee was using a hydraulic-pressured torque wrench to torque a bonnet connection on a valve when the elbow section of the torque head released pressure, resulting in a pressure cut/injection into the employee's left palm.

Hospitalized Hand(s), except finger(s) Pressurized air blast

TechnipFMC

An employee was rigging chains to a crane to lift a zipper assembly. While the employee was taking slack out, their right index finger was caught between a chain and the zipper assembly. The fingertip was amputated to the nailbed.

TechnipFMC

An employee was function testing a flushing unit when the unit failed and the access panel was forced open as the filter housing ejected upward from the unit. The access panel struck the employee on his hard hat and he fell backward onto concrete, resulting in a fracture to their C1 vertebra.

TechnipFMC

An employee was hooking up a hose when the hose fell and crushed their fingertip.

TechnipFMC

Two employees were working together to rotate a wellhead adapter. Employee 1 was using an overhead hoist and lifting strap to lift one side of the adapter and place it on its opposite side. Employee 1 began to lower the adapter down, and Employee 2's left middle finger was caught in a pinch point between the lifting strap and the part, resulting in a fingertip amputation.

TechnipFMC

An employee was connecting a 4-inch metal flex hose to a connection point. The hose slipped off the connection point and pinched the employee's right leg against a wellhead isolation valve, causing an open fracture to the femur.

View TechnipFMC's full OSHA safety record →

TSA Processing - Montgomery

A temporary employee was carrying a nail gun through the warehouse when it hit his leg, activated, and fired a nail into the leg.

First Environmental, Inc.

An employee was working to assess the operation of a high-pressure water nozzle. The water system was activated and the employee was cut by high pressure water on his left hand where the palm meets the wrist. The employee was hospitalized.

American Industrial Services

An employee's left bicep was lacerated by high-pressure water during water blasting operations. The employee was hospitalized.

Johnson Industrial Coatings, LLC.

On October 5, 2025, an employee was pulling a pressure washer hose when it it disconnected from the cooker. The employee was struck by jets of high-pressure water, resulting in lacerations to their left thigh requiring surgery. The employee was hospitalized.

Tanksco, Inc.

An employee was sandblasting paint from a water tower when the blasting media sprayed across their forearm, resulting in an elbow injury that required hospitalization.

3S Services, LLC

An employee had been cleaning the work area. While lifting a saw, the employee's index finger was lacerated by the saw blade. A tendon was cut and required surgery.

Roby's Propane Gas

An employee was delivering home heating fuel when bees came from the ground and stung the employee's face, neck, torso, and hands. The employee proceeded to shut off the oil flow before losing consciousness. They were hospitalized due to an anaphylactic reaction.

Myers Trucking, Inc.

An employee was using a torch to loosen a bolt on a water trailer. Natural gas was present in the water and it ignited, causing a fire. The employee sustained third-degree burns to their upper leg.

Weatherford U.S., L.P.

An employee had been conducting crane operations. The employee went to stop a piece of oil and gas equipment for tubular running from falling over to the ground. Their right hand was caught between a rolling ladder and the equipment, resulting in fractures to the index and middle fingers. They were hospitalized and the middle finger required surgery.

Helmerich & Payne IDC Inc

An employee was working to install a drive belt on a water pump. He was holding the belt on both sides of the pulley, working to route it over the top. As he pulled down with his right hand, the pulley rotated and the belt slid over it, pulling his left little finger between the pulley and the belt. He suffered an amputation to the fingertip as well as a fracture to the ring finger.

Main Line Clinical Labs

An employee was closing a door when the door closed on their right index finger, resulting in a fingertip amputation.

Ardent Mills

An employee was walking into the motor control center (MCC) room when his right ring finger was caught in the hinge of a doorway. He sustained an open phalanx fracture, which resulted in a partial amputation above the first knuckle.

Zimmerman & Herr

An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.

McAneny Brothers, Inc.

An employee was pulling down a broken skid with a forklift. When the employee backed up the forklift to get the forks out of the skid he pulled down, he contacted the forks of another parked forklift, fracturing both of his legs. He was hospitalized.

Metz Culinary Management LLC

An employee was carrying cups back to the kitchen when her foot got caught on a cart and she fell face-first. During the fall, a piece of glass from a cup cut the inside of her mouth, severing an artery. She also sustained a laceration on her lower lip. The employee was hospitalized.