Caught or wedged between objects nonrunning · Amputations involving bone loss
At a glance
Federal OSHA recorded a severe workplace injury
at Naval Information Warfare Center Pacific - NIWC, 53560 Hull Street, SAN DIEGO, CALIFORNIA 92152
on — Amputations involving bone loss, affecting the Other finger(s) n.e.c..
Final narrative
An employee was on a pier mooring a small, rigid inflatable boat. Their fingers were caught between the boat recovery line and the pier piling when the recovery line came under significant strain due to rough seas, resulting in a severe laceration to the left index finger and medical amputation of the left middle finger.
HospitalizedAmputation Other finger(s) n.e.c. Motorboat, motorized yacht
An employee was changing a die in a press when the die slipped and crushed the employee's left index finger. The employee sustained an open facture of the tuft of the left distal phalanx and a partial amputation.
An employee was diagnosing the lack of flow of product to a powder bin. The employee removed the rotary star valve below the bin. While he was reinstalling the valve, his right middle finger was crushed between its shaft and its housing. The finger was partially amputated.
On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.
An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.
An employee was conducting routine maintenance on a mixer. New lid pins had been installed, and the employee was rotating by hand to ensure they had been installed correctly. The employee's left middle finger was caught between the lid and top of a pin. The momentum from the mixer continued, causing a crushing injury to the finger. The employee underwent a medical amputation from the top knuckle to the tip of the finger.
More severe injuries in this industry (NAICS 334511)
Two employees were removing a service lift platform from the back of a radar system. While handling the service lift platform, employee 2 was standing on the back of the radar and lost their footing, causing the service lift platform to shift and fall. The injured employee then fell from the top of the platform electronic subsystem (PES) to the floor, approximately 56 inches. The injured employee fractured his left elbow and left hip.
On June 27, 2025, an employee was walking out of the hangar when he tripped and fell on the concrete ramp. He sustained lacerations to his right elbow and right hand, and was hospitalized with a fractured right hip.
An employee was performing maintenance activities on a ladder when they fell approximately 46 inches to the ground, resulting in a fracture to the left pelvis/sacrum.
An employee was loading a 150-pound block of aluminum into a CNC machine when their right hand was struck by the block. The employee sustained a fracture and severed tendon to the index finger, as well as a laceration to the middle finger that required stitches.
An employee picked up material out of a cardboard box that was on the floor. As he was carrying the material, he stepped backward and tripped over the cardboard box, causing him to fall and suffer a compound fracture of his leg.
The injured employee was assisting a Department of Homeland Security (DHS) enforcement operation. During an apprehension, officers returned fire at a subject and struck the employee with a bullet. The employee sustained a gunshot wound to their right hand.
The injured employee was assisting in the disassembly phase after a radar array had been lowered and secured. The crew began removing load bearing pins from an overhead crane to free the radome. A load bearing pin was stuck. The injured employee went to remove the pin manually as a second team member applied pressure from the opposite side. The pin unexpectedly released and struck the injured employee s right thumb, resulting in partial amputation of the distal phalanx including an open distal phalanx fracture and nail bed laceration.
At about 3:10 p.m. on October 3, 2025, an employee was inspecting a car. Two dogs that had been in another car were leashed and tethered to a bollard. As the employee inspected the first car along with a narcotics detection dog, one of the other dogs came loose and attacked the narcotics dog. The employee was separating the dogs when the other dog bit his left ring finger. The last joint of the finger was injured and part of it was bitten off.
An employee was preparing a bundle of green onions for chopping. While holding the bundle in his left hand, he made his first cut using a 9-inch kitchen knife held in his right hand. The knife contacted the tip of his left thumb, resulting in an amputation of approximately 0.5 inches of the thumb that required hospitalization.