105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Nucor Steel Arkansas

Struck by running powered equipment unspecified · Amputations involving bone loss

Federal OSHA recorded a severe workplace injury at Nucor Steel Arkansas, 7301 East CR 142, BLYTHEVILLE, ARKANSAS 72315 on — Amputations involving bone loss, affecting the Other finger(s) n.e.c..

An employee was working on an outage on a ladle metallurgy furnace when the electrode arm came down and struck their hand, amputating their middle and index fingers.

Amputation Other finger(s) n.e.c. Forging machinery

Nucor Steel Arkansas

An employee was working to de-chock a set of four high work rolls which were being removed from the roll mill for maintenance. While he was removing the spreader bar, he was caught in a pinch point between the spreader bar and a roll resulting in amputation of the right pinky fingertip.

Nucor Steel Arkansas

An employee was walking towards a ramp over a large pit. The employee missed the ramp and fell into the pit, landing on the floor approximately 30 feet below. The employee sustained a fractured skull, broken T-5 and T-7 vertebrae, a collapsed lung, and head trauma.

View Nucor Steel Arkansas's full OSHA safety record →

Inteplast Group

An employee was removing plastic material from a production line when the machine cycled and amputated his left index, ring, and little fingers.

TABER EXTRUSIONS, LLC

An employee's left arm was caught in the fingers or jaws of the head stretcher machine, resulting in a laceration. The employee was hospitalized.

American Flowform and Machining, LLC

Two employees were setting up a mandrel in the spindle of a machine. The mandrel was side-shifted while an employee's hand was on the mast of a powered industrial truck. The employee suffered crushing injuries that resulted in amputations to the middle and ring fingertips.

Omya Inc.

An employee was working to remove a product blockage from a piece of equipment. The employee was struck by a metal bar near the deck of the pin mixer equipment and sustained blunt force trauma to the torso.

Floworks International LLC

An employee fell while entering the building. The employee was hospitalized with a fractured ankle and required surgery.

Big River Steel, LLC

An employee was doing a cable change on top of an electric overhead traveling (EOT) crane. They were positioned between the cable drum and the drive shaft. While rotating the cable drum, the employee reached for the new cable that was to be installed. The grease fitting on the drive shaft caught their fall harness and pulled them underneath the drive shaft. The employee was pinned between the drive shaft and two pieces of angle steel, resulting in a fracture to their left hip.

Keystone Consolidated Industries, Inc.

An employee was working to close a furnace door. The hydraulic mechanism that opens and closes the furnace door was non-operational and had been disconnected to allow the furnace door to be opened manually. As the employee was releasing the pins that held the door open, the door and the hydraulic cylinder fell, pinching their left hand between the hydraulic cylinder's base plate and the furnace. The employee suffered amputation of the little fingertip.

Commercial Metals Company

A rolling mill was shut down due to a cobble between two mill stands. The injured employee was cleaning the cobble from the delivery side of stand A, while another employee went to the control panel to move stand B and stand A moved instead. The injured employee's right thumb got caught between the delivery guide of stand A and the looper trough. The tip of his thumb required surgical amputation to the bone to allow for stitches.

Metalcraft of Mayville, Inc.

An employee was helping another employee load stock material onto a press brake when the stock slipped. The injured employee's right index finger was caught between the press brake die and the stock, resulting in amputation at the first knuckle.

NATIONAL MILL MAINTENANCE, LLC

An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.

The Goodyear Tire & Rubber Company

On October 25, 2025, an employee was stringing up a new reel of tire tread on a machine. The employee pulled a 6-inch tail and proceeded to spool up the liner. As the machine was jogged to begin the liner wrapping process, the liner caught the employee's glove and pulled their right arm into the liner, causing a fracture to the arm.

Big River Steel, LLC

An employee was doing a cable change on top of an electric overhead traveling (EOT) crane. They were positioned between the cable drum and the drive shaft. While rotating the cable drum, the employee reached for the new cable that was to be installed. The grease fitting on the drive shaft caught their fall harness and pulled them underneath the drive shaft. The employee was pinned between the drive shaft and two pieces of angle steel, resulting in a fracture to their left hip.

American Tile & Marble Co., Inc

An employee was helping two other employees to push a pallet of tile on a loading dock. He suffered a broken fibula and was hospitalized.

Johnson Industrial Coatings, LLC.

On October 5, 2025, an employee was pulling a pressure washer hose when it it disconnected from the cooker. The employee was struck by jets of high-pressure water, resulting in lacerations to their left thigh requiring surgery. The employee was hospitalized.