Struck by running powered equipment n.e.c. · Amputations involving bone loss
At a glance
Federal OSHA recorded a severe workplace injury
at Takkion Ops Management LLC, 12306 20th St SE, LUVERNE, NORTH DAKOTA 58056
on — Amputations involving bone loss, affecting the Finger or thumb tip(s), nail(s).
Final narrative
An employee was operating a hydraulic torque tool on a main bearing. The tool activated before the torque head was on the bolt. The employee's left little finger became caught between the reaction arm and the main bearing. The finger was crushed and the fingertip was amputated.
Amputation Finger or thumb tip(s), nail(s) Gripping and turning handtools unspecified
After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.
An employee was using a vertical band saw to cut a thick piece of rubber material. While being cut, the material shifted, causing the employee s right hand to contact the moving blade. The employee's thumb was amputated below the knuckle. The employee was hospitalized, undergoing surgery.
More severe injuries in this industry (NAICS 221115)
Two employees were removing a circuit breaker. The injured employee was using wrenches in the removal process. One of the wrenches contacted an adjacent door, resulting in an arc flash. The employee suffered burns to their neck, face, and ear, as well as momentary vision loss due to the flash.
An employee was ascending the wind tower when their right arm was caught between the lift and the ladder. The employee sustained a right elbow injury and was hospitalized.
On 3/27/2025, at 9:57 AM, an employee was performing switching work including installing electrical grounds when an arc flash occurred. Personal protective equipment (PPE) was worn at the time, including an arc flash hood, shirt, and pants. The employee suffered burns and was hospitalized.
An employee was cleaning dirt out of a contactor using a hand-held blower and contact cleaner. An arc flash occurred, and the employee sustained burns to the right side of their face and both hands.
On February 16, 2025, an employee was descending a ladder on the third deck after completing rigging at a wind farm. Their left foot slipped on the penultimate rung and their leg became wedged between the ladder rungs and a horizontal bracket. The employee then landed on the second deck resting platform, resulting in a leg fracture above the ankle.
An employee was on the ground working to close a trailer door. The door was caught by the wind and blew the employee backward. He landed on his back and sustained four fractured ribs, requiring hospitalization.
An employee was walking on top of boiler to close a valve. The employee fell off the boiler and landed on the floor, sustaining fractured ribs. The employee was hospitalized.
An employee was exiting a loader and coming down the ladder. His hand slipped off the railing and he fell backward onto sandy ground, landing on his side. The employee was hospitalized with a fractured pelvis and a rotator cuff tear.