Caught or wedged between objects nonrunning · Amputations, avulsions, enucleations unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Darby Equipment Company, LLC, 2940 N. Toledo Ave., TULSA, OKLAHOMA 74115
on — Amputations, avulsions, enucleations unspecified, affecting the Other finger(s) n.e.c..
Final narrative
An employee was removing a winch-line hook from a mandrel after they had completed bending a 24-inch diameter pipe. As he was unhooking the hook, the pipe moved and pinched his left index finger against the mandrel. The employee's finger sustained an partial amputation.
Amputation Other finger(s) n.e.c. Pipes, tubes metal
More severe injuries at Darby Equipment Company, LLC
An employee was cleaning and lubricating the drive chain on a pipe coating machine. The rag he was using to remove excess oil was caught in the machine, which resulted in his hand being pulled in. He suffered a partial amputation of the left index finger.
An employee was changing a die in a press when the die slipped and crushed the employee's left index finger. The employee sustained an open facture of the tuft of the left distal phalanx and a partial amputation.
An employee was diagnosing the lack of flow of product to a powder bin. The employee removed the rotary star valve below the bin. While he was reinstalling the valve, his right middle finger was crushed between its shaft and its housing. The finger was partially amputated.
On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.
An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.
An employee was conducting routine maintenance on a mixer. New lid pins had been installed, and the employee was rotating by hand to ensure they had been installed correctly. The employee's left middle finger was caught between the lid and top of a pin. The momentum from the mixer continued, causing a crushing injury to the finger. The employee underwent a medical amputation from the top knuckle to the tip of the finger.
More severe injuries in this industry (NAICS 333132)
Employees were replacing a 24" pig trap door. A strap was shackled on the pig trap door and connected to a forklift. Welders began to cut the door off. An employee was holding onto the door when the cut was finished. The door shifted and caught his fingers, resulting in a hand injury and amputation.
An employee was fitting an arbor fixture into a rotor housing to be reworked. The rotor is moved by a hoist. The arbor was being lowered into the rotor housing when the arbor slipped down onto his hand and amputated a portion of his left thumb.
A crew was tripping out of the hole with an electrical submersible pump (ESP) in the process of swapping tubing tong heads to break down the ESP. An employee's left arm was caught and pinched by the tubing tongs. The employee sustained three lacerations and a fracture to the arm.
On May 21, 2025, at approximately 3:40 PM, a machinist was preparing a CNC lathe machine for it's next run. He was closing the machine door to complete the tooling setup when the door crushed his right middle finger. The employee required a surgical amputation to his fingertip.
An employee was helping to move a 1,300-pound coil on a cart. The steel caster hit a crack in the concrete, the weld holding the caster onto the cart broke, and the coil and cart tipped over onto the employee. He was hospitalized with a laceration on his forehead and a pelvic fracture on his right side.
An employee was working in the food service warehouse when he experienced chest pain, difficulty breathing, and lost consciousness. The employee sustained carbon monoxide poisoning.
An employee was cutting a piece of metal rod with a metal cutting machine. His right middle finger became caught between the rod and the machine's table. The employee's fingertip was partially amputated.
An employee was working at her desk. She went to stand up and fell to the floor beside the desk. The employee sustained a hip displacement and required surgery.
An employee was processing wood boards at a chop saw when the saw malfunctioned and the blade cut her left hand and fingers. She was hospitalized and her little finger was surgically amputated.