105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Darby Equipment Company, LLC

Caught or wedged between objects nonrunning · Amputations, avulsions, enucleations unspecified

Federal OSHA recorded a severe workplace injury at Darby Equipment Company, LLC, 2940 N. Toledo Ave., TULSA, OKLAHOMA 74115 on — Amputations, avulsions, enucleations unspecified, affecting the Other finger(s) n.e.c..

An employee was removing a winch-line hook from a mandrel after they had completed bending a 24-inch diameter pipe. As he was unhooking the hook, the pipe moved and pinched his left index finger against the mandrel. The employee's finger sustained an partial amputation.

Amputation Other finger(s) n.e.c. Pipes, tubes metal

Darby Equipment Company, LLC

An employee was cleaning and lubricating the drive chain on a pipe coating machine. The rag he was using to remove excess oil was caught in the machine, which resulted in his hand being pulled in. He suffered a partial amputation of the left index finger.

View Darby Equipment Company, LLC's full OSHA safety record →

Great Dane Ltd. Partnership

An employee was changing a die in a press when the die slipped and crushed the employee's left index finger. The employee sustained an open facture of the tuft of the left distal phalanx and a partial amputation.

Milk Specialties Global

An employee was diagnosing the lack of flow of product to a powder bin. The employee removed the rotary star valve below the bin. While he was reinstalling the valve, his right middle finger was crushed between its shaft and its housing. The finger was partially amputated.

GXO Logistics

On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.

Zimmerman & Herr

An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.

Certainteed Gypsum West Virginia, Inc

An employee was conducting routine maintenance on a mixer. New lid pins had been installed, and the employee was rotating by hand to ensure they had been installed correctly. The employee's left middle finger was caught between the lid and top of a pin. The momentum from the mixer continued, causing a crushing injury to the finger. The employee underwent a medical amputation from the top knuckle to the tip of the finger.

Renegade Group LLC

Employees were replacing a 24" pig trap door. A strap was shackled on the pig trap door and connected to a forklift. Welders began to cut the door off. An employee was holding onto the door when the cut was finished. The door shifted and caught his fingers, resulting in a hand injury and amputation.

Guidant Measurement

An employee was fitting an arbor fixture into a rotor housing to be reworked. The rotor is moved by a hoist. The arbor was being lowered into the rotor housing when the arbor slipped down onto his hand and amputated a portion of his left thumb.

Aztecwell

A crew was tripping out of the hole with an electrical submersible pump (ESP) in the process of swapping tubing tong heads to break down the ESP. An employee's left arm was caught and pinched by the tubing tongs. The employee sustained three lacerations and a fracture to the arm.

Hunting Energy Services

On May 21, 2025, at approximately 3:40 PM, a machinist was preparing a CNC lathe machine for it's next run. He was closing the machine door to complete the tooling setup when the door crushed his right middle finger. The employee required a surgical amputation to his fingertip.

Rae Corporation

An employee was helping to move a 1,300-pound coil on a cart. The steel caster hit a crack in the concrete, the weld holding the caster onto the cart broke, and the coil and cart tipped over onto the employee. He was hospitalized with a laceration on his forehead and a pelvic fracture on his right side.

Meeco Sullivan

An employee was cutting a piece of metal rod with a metal cutting machine. His right middle finger became caught between the rod and the machine's table. The employee's fingertip was partially amputated.

Edward Jones Investments

An employee was working at her desk. She went to stand up and fell to the floor beside the desk. The employee sustained a hip displacement and required surgery.

Burgess Manufacturing of Oklahoma Inc.

An employee was processing wood boards at a chop saw when the saw malfunctioned and the blade cut her left hand and fingers. She was hospitalized and her little finger was surgically amputated.