105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Three Phase Line Construction Inc.

Indirect exposure to electricity greater than 220 volts · Fractures and burns

Federal OSHA recorded a severe workplace injury at Three Phase Line Construction Inc., Marcy Substation, MARCY, NEW YORK 13403 on — Fractures and burns, affecting the Trunk and other upper extremities.

An employee was removing a jumper from the center phase of a de-energized transmission line. When the jumper was removed, the induction current on the line (induced by nearby energized transmission lines) entered the employee's left hand and exited through his left hip area. The employee was hospitalized with burn wounds to left hand and lower right abdomen, as well as a compression fracture to his T5, T6, and T7 vertebrae.

Hospitalized Trunk and other upper extremities Power lines, transformers, convertors

Three Phase Line Construction, Inc.

An employee suffered a leg injury after being struck by a piece of wood. An excavator dropped a utility pole which subsequently caused a piece of wood to hit an adjacent worker.

View Three Phase Line Construction Inc.'s full OSHA safety record →

Paul Conard Construction Co., Inc

An employee was guiding the pouring end of a concrete pump truck's boom while standing on top of 4-foot wall forms. The boom contacted power lines and the employee was shocked. The employee sustained third-degree burns on the entry and exit path of the electricity, and also sustained first- and second-degree burns to their torso and legs.

Great Plains Health Urgent Care

An employee was cleaning a laptop charging cable when lightning struck. The employee began experiencing heart palpitations and hearing loss, resulting in hospitalization.

Bowman Energy Services LLC

An employee was acting as a spotter for a forklift operator. While its forks were being raised, the forklift came into contact with a power line. The employee was touching the forklift's metal frame at the time and was shocked on the left palm. The employee suffered burns to both the left palm and the sole of the left foot.

Smyrna Ready Mix Concrete, LLC

A Smyrna Ready Mix delivery driver was delivering concrete to a job site. He backed his truck up to a pump truck, then began preparing it to transfer the concrete. The pump truck's boom moved and came into contact with a power line, which broke and fell onto the employee's delivery truck. The employee was knocked to the ground and suffered electrical burns to both arms and both feet.

Riggs Tree Service, LLC

An employee was clearing a right-of-way for utility lines when a small sapling was cut and fell, causing vines to pull a tree down and into power lines. The vines also became electrified and were contacting the employee's feet, shocking them. The employee became ill and experienced slurred speech and convulsions, resulting in hospitalization.

Smart Building Technologies - A Fidelity Company

An employee was troubleshooting the control setup for a variable air volume box above a ceiling. The employee's hand came into contact with an exposed, energized 277-volt wire that had loosened from its terminal on the box's assembly. He was shocked and fell off a ladder. His left hand passed across the ceiling grid and was lacerated. He also suffered an electrical burn to the right hand and was hospitalized.

Abbott Electric Inc

An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.

Mintcrest Corp

An employee was standing on an A-frame ladder approximately 6 feet above the floor while he attached a suspended light fixture to the ceiling. The employee lost balance, and fell to the tiled floor below, sustaining blunt force trauma to his head.

Cupertino Electric, Inc.

An employee was inspecting the overhead area of a single-person lift and repositioning the lift through a double doorway. As they were transitioning through the doorway, they were caught between the doorframe and the vertical mast of the lift. The employee was hospitalized with injuries to the nose, left maxillary sinus, left orbital bone, and left jaw, with fractures at the maxillary sinus area.

Swedberg Electric, LLC

The injured employee was performing routine maintenance on a fan belt/pulley. The injured employee and another person were moving the pulley back and forth manually to find a bearing issue. The injured employee's left ring finger got caught between the belt and the pulley wheel, resulting in a soft tissue amputation.

Garden Angels New York LLC

An employee was cleaning leaves with a backpack blower when he fell from a ladder, resulting in injuries to his head, neck, and back.

Cashless Tolling Constructors

An employee was operating a battery-powered broom to clean demolition debris off the top of the outermost bridge girder. The girder was approximately 11 feet above the demolition scaffold below. The employee fell approximately 8 feet to wind bracing below. The employee was hospitalized with a pelvis/tailbone fracture. Fall protection was in place at the time.

NYU Langone Hospital-Brooklyn

An employee slipped while descending in a stairwell, fell, and suffered multiple contusions/bruises to the head, neck, shoulders, knees, and back. She was hospitalized.

VILLAGER CONSTRUCTION, INC.

An employee was directing trucks as they entered and left a highway work zone. A vehicle struck them, resulting in multiple fractures and other injuries. The employee was hospitalized.