Caught or wedged between objects nonrunning · Amputations, avulsions, enucleations unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Bar-S Foods Co., 500 S. Bar S Blvd., ALTUS, OKLAHOMA 73521
on — Amputations, avulsions, enucleations unspecified, affecting the Finger or thumb tip(s), nail(s).
Final narrative
An employee was assembling a casing stuffing machine after cleaning. While placing the inner jug into the housing assembly, their left little fingertip was lacerated by the inner jug. The employee sustained a partial fingertip amputation.
Amputation Finger or thumb tip(s), nail(s) Food and beverage processing machinery n.e.c.
An employee was inspecting a ham grinder when the grinder's paddles struck her right hand, resulting in lacerations and fractures to her hand and fingers.
An employee had a water spray hose on her shoulder when she leaned in to look at a meat cutter machine during inspection. The water spray activated the machine and amputated the employee's left middle fingertip.
An employee was cleaning the blender auger and slipped and fell, hitting the framework of the equipment and fracturing ribs. The employee was hospitalized.
An employee was changing a die in a press when the die slipped and crushed the employee's left index finger. The employee sustained an open facture of the tuft of the left distal phalanx and a partial amputation.
An employee was diagnosing the lack of flow of product to a powder bin. The employee removed the rotary star valve below the bin. While he was reinstalling the valve, his right middle finger was crushed between its shaft and its housing. The finger was partially amputated.
On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.
An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.
An employee was conducting routine maintenance on a mixer. New lid pins had been installed, and the employee was rotating by hand to ensure they had been installed correctly. The employee's left middle finger was caught between the lid and top of a pin. The momentum from the mixer continued, causing a crushing injury to the finger. The employee underwent a medical amputation from the top knuckle to the tip of the finger.
More severe injuries in this industry (NAICS 311612)
After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.
An employee was using a de-clipping machine to cut the metal clips off of sausage sticks. As the employee put a link of sausages into the machine, their hand slipped into the point of operation. A piston pinched the employee's left index finger, causing a partial amputation.
An employee was operating a small tabletop grinder in a food safety quality assurance lab. She was stuffing meat down the grinder's chute when the grinder caught her right hand. Its auger caused an amputation to her middle finger and a partial amputation to her index finger.
A maintenance employee was removing an inspection plate from an industrial cooker. Hot liquid spilled onto him and burned his hands, arms, and torso area. He was hospitalized.
An employee was helping to move a 1,300-pound coil on a cart. The steel caster hit a crack in the concrete, the weld holding the caster onto the cart broke, and the coil and cart tipped over onto the employee. He was hospitalized with a laceration on his forehead and a pelvic fracture on his right side.
An employee was working in the food service warehouse when he experienced chest pain, difficulty breathing, and lost consciousness. The employee sustained carbon monoxide poisoning.
An employee was cutting a piece of metal rod with a metal cutting machine. His right middle finger became caught between the rod and the machine's table. The employee's fingertip was partially amputated.
An employee was working at her desk. She went to stand up and fell to the floor beside the desk. The employee sustained a hip displacement and required surgery.
An employee was processing wood boards at a chop saw when the saw malfunctioned and the blade cut her left hand and fingers. She was hospitalized and her little finger was surgically amputated.