Federal OSHA recorded a severe workplace injury
at Norton Equipment Company, 60 Amy Lane, BYHALIA, MISSISSIPPI 38611
on — Fractures , affecting the Other finger(s) n.e.c..
Final narrative
An employee was removing a hydraulic cylinder from a baler. As he removed the bolts, the cylinder came down and fractured his left middle finger.
Hospitalized Other finger(s) n.e.c. Hydraulic and pressurized cylinders
An employee was walking past a crossover conveyor when a ramp came down and hit them in the back. The employee sustained a broken back vertebra, as well as a concussion, and was hospitalized.
An employee was unloading frameless mirrors from a trailer. When unstrapped, the mirrors fell over onto the employee, who suffered a skull fracture, a brain bleed and blood clot, a broken left ankle, and lacerations.
A temporary employee was rigging secondary steel when the steel joist fell to the ground and struck his lower left leg, resulting in fractures to the tibia and fibula.
Two maintenance employees were dismantling a machine part (steel cylindrical rollers) on the ground. After unbolting a portion, part of the assembly fell approximately 6 inches onto one employee's left little finger. The employee was hospitalized and about 3/4" of their little finger above the top joint was surgically amputated.
An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.
An employee was climbing a ladder to inspect a vent in a restaurant dining area. The ladder slid out on the floor and the employee fell approximately 12 feet onto the ladder and the floor. He was hospitalized with a dislocated shoulder and a back injury.
An employee was operating a lift truck when it struck a stationary lift truck. His left thumb was pinched between the two lift trucks, resulting in a partial amputation.
An employee was disassembling a pressurized unit using a driver drill. When the unit was disassembled, it caused a kickback from the tube head, causing the drill to strike the employee's left forearm. They sustained a diaphyseal fracture to their left radius and ulna, which required surgery.
After repairing a piece of industrial equipment, an employee had brake-cleaning liquid on his gloves. A lighter ignited the liquid, and the employee's hands were severely burned.
An employee was checking a pole-type transformer tank for leaks. A hydraulic clamping device was lowered onto his right thumb and crushed it against the sharp edge of the bottom of the tank. He suffered a partial transphalangeal amputation to the thumb.
The injured employee was standing behind a table. She jumped out to scare another employee, but tripped and fell on the tile floor, injuring her right ankle/foot. She was hospitalized with a dislocated ankle that required surgery.
An employee was going into a trailer to mark product for shipment and the trailer pulled away from the dock. The employee fell out of the trailer, contacted the dock plate, and then fell to the ground. The employee was hospitalized with a punctured lung, fractured ribs, and contusions.
An employee was hooking up bundled tie-downs with a chain. While he was holding a hook, the other hook was unlocked. This caused the employee's hook to slide down and pinch his right index finger between the chain and the shackle. He suffered an amputation to the fingertip (without bone loss), as well as an open fracture.
An employee was operating a gas tugger to lift metal sheeting. His left hand was pulled into the pulley, which crushed his left thumb, resulting in avulsions and other tissue damage. He was hospitalized and required surgery.