Struck by dislodged or detached object(s) · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at Berry Global Incorporated, 20 Elmwood Avenue, MOUNTAIN TOP, PENNSYLVANIA 18707
on — Fractures , affecting the Lower leg(s).
Watch Berry Global Incorporated — freeGet an email when a new federal OSHA severe-injury report for Berry Global Incorporated is published. One employer, no account, unsubscribe in one click.
Final narrative
The injured employee was standing near a plastic roll machine while another employee was taking a quality control sample of the plastic film. The machine was powered off at the time of sampling. Upon completion of the sampling, the machine was started up again and a metal shaft was ejected. The metal shaft still had a roll of plastic on it; it weighed approximately 920 pounds and it was positioned approximately 8 feet above the ground. The metal shaft struck the injured employee, who then fell into the second employee. The second employee fell to the ground and sustained contusions but was not hospitalized. The injured employee's left leg was broken below the knee and the employee was hospitalized.
Hospitalized Lower leg(s) Vehicle and machine parts unspecified
An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.
A service crew was pulling a pump and motor from a well. After breaking a joint of pipe loose from another joint, an employee grabbed the chain tongs to prevent the pipe from spinning in the well, so the crew could continue taking it apart. The bolt that attaches the chain to the handle of the chain tongs broke, causing the chain to swing around and strike the employee's lower right leg. The chain severely punctured his leg and fractured his tibia.
An employee was using a handheld grinder to cut a bolt. The grinding wheel broke apart and a fragment struck the employee s right hand, causing a laceration to the palm near the little finger.
An employee was operating a brake press when the top die broke, causing the bottom die to roll out and onto the employee's legs. Both of the employee's legs were crushed below the knee, and both legs were partially amputated. The employee's left leg was also fractured above the knee.
A pressurized aircraft nose landing gear strut assembly was being disassembled. The gland nut dislodged under pressure and made contact with an employee's left hand, breaking it.
More severe injuries in this industry (NAICS 326113)
A subcontracted engineer was advising maintenance how to make a modification to the embossing roll system on a new line. Maintenance was bringing the motor and gearbox down with a crane. The load shifted when it was a few inches from the ground. The engineer went to catch/maneuver the gearbox and the fingers on his left hand were crushed between the I-beam base of the gearbox and the concrete floor. A finger was amputated.
On July 30, 2025, an employee was assisting co-workers in using a hoist to position an injection molding tool onto a work table. As the tool was being lowered, the slide section shifted, trapping and amputating the employee's right thumb tip.
An employee was manually lifting a film roll when their right middle fingertip was pinched between the roll and a metal beam, resulting in a fingertip amputation.
At about 10:00 a.m. on July 13, 2025, an employee was cleaning the adhesive from running rollers using a rag soaked in cleaning solvent to prevent contamination. The rag was caught between two rollers and pulled the employee's right hand between the rollers. The employee sustained right hand crushing injuries, de-gloving injuries (palmer and dorsal sides), and fractures. The employee was hospitalized and required surgery. The machine was not locked out/tagged out at the time.
An employee working on a sheet line was removing masking from the underside of plastic sheeting that was being lifted by a vacuum lift. The plastic sheet measured 4 feet wide, 14 feet long, and approximately 1 inch thick, and it weighed approximately 300 pounds. The vacuum lost suction and dropped the plastic sheet onto the employee's arm, pinning it between two sheets and resulting in a broken right forearm.
An employee was walking into the motor control center (MCC) room when his right ring finger was caught in the hinge of a doorway. He sustained an open phalanx fracture, which resulted in a partial amputation above the first knuckle.
An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.
An employee was pulling down a broken skid with a forklift. When the employee backed up the forklift to get the forks out of the skid he pulled down, he contacted the forks of another parked forklift, fracturing both of his legs. He was hospitalized.
An employee was carrying cups back to the kitchen when her foot got caught on a cart and she fell face-first. During the fall, a piece of glass from a cup cut the inside of her mouth, severing an artery. She also sustained a laceration on her lower lip. The employee was hospitalized.