Chemours Company

Exposure through intact tissue · Chemical burns, corrosions degree unspecified

Federal OSHA recorded a severe workplace injury at Chemours Company, 4127 Hwy 361, GREGORY, TEXAS 78359 on — Chemical burns, corrosions degree unspecified, affecting the Other multiple ear(s), facial locations.

Watch Chemours Company — free Get an email when a new federal OSHA severe-injury report for Chemours Company is published. One employer, no account, unsubscribe in one click.

An employee was rebuilding a valve. He started to apply steam to the valve when there was a release of hydrogen fluoride and tar. The employee sustained burns to their right cheek and loss of vision in the right eye.

Hospitalized Other multiple ear(s), facial locations Hydrofluoric acid

Sharp International Services, LLC

An employee was removing a hose from a chemical tank after filling the tank with hexamethylenediamine (HMD). He checked the line to ensure that the hose was clear, then disconnected the hose at the connection. Residual chemical sprayed onto his face, causing a second-degree burn. He was hospitalized.

PCI Nitrogen, LLC

A shipping/receiving operator was working on a loading rack, loading a railcar. A 2-inch discharge cap failed and released pressure along with sulfuric acid from the railcar. The acid sprayed onto the employee, who suffered burns to the chest and the lower facial area. The employee was hospitalized.

American Equipment Systems, LLC

An employee was pressure washing truck scales when they were splashed with water and an unknown chemical on their leg and immediately experienced a burning sensation. The employee was hospitalized with a chemical burn and required surgery.

Innovative Chemical Technologies

An employee was on a ladder disconnecting a 1-inch hose, known to have last carried acrylic acid that had been drained. When the hose was disconnected, residual acid dripped onto the employee's shoulder/arm area, causing a second-degree chemical burn.

Pen Gulf, Inc.

Employees were removing scaffolding that was used to repair an ion exchange tank. The line was undergoing the regen process when a piece of scaffold struck a PVC pipe that transported hydrochloric acid (HCl). The injured employee was placing material inside a scaffold rack when he was sprayed in the face with HCl and sustained chemical burns to his eyes, face, chest, right arm, and left leg.

HEXPOL Compounding PC, Inc.

Two employees were lifting a roll of steel poly bar (50 inches and approximately 150 pounds) from ground level to a height of 4 feet at the 66-inch rubber calendar. One employee dropped the roll, resulting in the poly bar contacting the injured employee's right knee. The employee was hospitalized with fractured right patella.

Lyondellbasell

Employees were loading a 295-pound transformer onto a pickup truck using a forklift. The injured employee was acting as the spotter. The transformer hit the tailgate of the pickup truck and the spotter's right hand was struck by the transformer, resulting in amputation of the ring fingertip.

STEPAN COMPANY

An employee was wearing full PPE while emptying a 55-gallon drum of phosphorus pentoxide and fainted, collapsing and striking their head against the ground. The employee was hospitalized and it is likely that heat caused by wearing full body PPE contributed to fainting.

BASF Corporation

An employee was troubleshooting a plug in the super-absorbent polymer line. The employee opened an inspection port and their right hand was caught in a rotary valve, resulting in the amputation of four fingers between the knuckle and the first joint.

Galata Chemicals LLC

An employee was conducting a quality control measure by taking a chemical sample for lab analysis. When the employee was opening the sample point, it broke off and crude 2-Ethylhexyl thioglycolate (EHTG) shot out at 265 degrees, and it covered the employee's legs and right arm and splashed the right side of their face. The employee was hospitalized with first- and second-degree burns to their right thigh, lower right knee, inner left thigh, and upper left forearm.

T G Meat Center LLC

After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.

Professional Flooring Supply

An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.

EnviroSafe Demil LLC

An employee was inspecting flares processes. The employee received burns to the front side of the body, face and arm from the flares.

Inteplast Group

An employee was removing plastic material from a production line when the machine cycled and amputated his left index, ring, and little fingers.

Regency IHS of Fairwinds Halletsville, LLC

An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.