Exposure through intact tissue · Chemical burns, corrosions degree unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Peoples Cartage, Inc, 4301 Camden Avenue, PARKERSBURG, WEST VIRGINIA 26101
on — Chemical burns, corrosions degree unspecified, affecting the Hand(s) and finger(s).
Final narrative
An employee put on nitrile gloves and sustained chemical burns to their hands because the gloves were contaminated with bromine. The employee was hospitalized.
Hospitalized Hand(s) and finger(s) Nonflammable Liquids and Solids unspecified
An employee was removing a hose from a chemical tank after filling the tank with hexamethylenediamine (HMD). He checked the line to ensure that the hose was clear, then disconnected the hose at the connection. Residual chemical sprayed onto his face, causing a second-degree burn. He was hospitalized.
A shipping/receiving operator was working on a loading rack, loading a railcar. A 2-inch discharge cap failed and released pressure along with sulfuric acid from the railcar. The acid sprayed onto the employee, who suffered burns to the chest and the lower facial area. The employee was hospitalized.
An employee was pressure washing truck scales when they were splashed with water and an unknown chemical on their leg and immediately experienced a burning sensation. The employee was hospitalized with a chemical burn and required surgery.
An employee was on a ladder disconnecting a 1-inch hose, known to have last carried acrylic acid that had been drained. When the hose was disconnected, residual acid dripped onto the employee's shoulder/arm area, causing a second-degree chemical burn.
Employees were removing scaffolding that was used to repair an ion exchange tank. The line was undergoing the regen process when a piece of scaffold struck a PVC pipe that transported hydrochloric acid (HCl). The injured employee was placing material inside a scaffold rack when he was sprayed in the face with HCl and sustained chemical burns to his eyes, face, chest, right arm, and left leg.
More severe injuries in this industry (NAICS 493110)
On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.
An employee was operating an extruder and performing a spool swap over from the right spindle to the left spindle. After rewiring the new spool, the employee's clothing got caught in the turning shaft when the left spindle started back up. The employee's left arm was pulled into the machine, resulting in a fractured humerus and lacerations to her triceps. She was hospitalized and required surgery.
An employee was resetting a warehouse racking system utilizing an order picker. They fell approximately 5 feet from the order picker to the concrete floor and sustained fractured ribs.
An employee was conducting routine maintenance on a mixer. New lid pins had been installed, and the employee was rotating by hand to ensure they had been installed correctly. The employee's left middle finger was caught between the lid and top of a pin. The momentum from the mixer continued, causing a crushing injury to the finger. The employee underwent a medical amputation from the top knuckle to the tip of the finger.
An employee was climbing down a 15-foot multipurpose ladder. The employee fell about 8 feet, landing on the concrete floor and the ladder itself. The employee suffered several injuries, all on the right side: broken ribs, a broken sternum, a broken temporal bone, broken shoulder, multiple fractures to the cheekbone, and a brain bleed.
An employee was rolling up the landing gear on his trailer when the handle began to unwind and struck his face, fracturing his jaw. The employee was hospitalized and required surgery.