Struck by running powered equipment during maintenance, cleaning, testing · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at Whitehead Die Casting Company, 2600 SW Atlanta Hwy, GAINESVILLE, GEORGIA 30504
on — Fractures , affecting the Rib(s), oblique area.
Final narrative
An employee was checking the die casting machine when the cavity access door closed behind him and the employee sustained eight fractured ribs. The employee was hospitalized.
Hospitalized Rib(s), oblique area Casting machinery
A temporary employee turned off a planer machine, opened the housing, and began clearing a jam. The machine's spinning blade caught his right hand and degloved the index finger.
An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.
A production sanitation employee was pre-rinsing an incline conveyor and noticed cheese stuck between the belt idler. The employee went to remove the cheese and their glove got caught and pulled their left forearm into the conveyor. The employee's arm was fractured. The machine was not locked out/tagged out at the time.
More severe injuries in this industry (NAICS 331523)
An employee was adjusting the oscillator pressure injector on a die-cast machine when his right thumb contacted the adjustment handle. The machine oscillated and closed on his right thumb. The tip of the thumb was pinched and amputated between the die and the handle.
An employee in the melt department was getting ready to put a recirculation pump into the pump housing area. He first put the pump in a cabinet to warm it up to avoid thermal shock. It shifted and the cold refractory contacted the hot metal. Molten metal contacted the employee, resulting in third-degree burns between their knee(s) and ankle(s). The employee was wearing some personal protective equipment (PPE) at the time but this was breached by the molten metal.
On May 15, 2025, an employee was assisting with troubleshooting an issue with a die in a die casting machine. While unjamming the machine, the employee's finger was caught between a section of the die and a wooden spacer. The employee's left middle fingertip was amputated.
An employee was using a vertical band saw to cut a piece of square metal tubing when their left hand contacted the saw blade and their middle finger was amputated.
An employee was preparing to load a truck. They opened the dock door and were putting the dock plate in place, using their foot to push the plate down. The employee tripped and their right hand became caught in the hinge of the dock plate. Their middle and ring fingertips were amputated.
An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.
During a workshop meeting in a hotel, an employee heard a drilling noise, so he walked outside to see what it was. An explosion occurred (possible gas line) and his face, ear, and hair were burned. He also fell and sustained a pelvic fracture.
An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.