Struck by running powered equipment during maintenance, cleaning, testing · Amputations involving bone loss
At a glance
Federal OSHA recorded a severe workplace injury
at Delice Global Inc, 150 ROOSEVELT PLACE, PALISADES PARK, NEW JERSEY 07650
on — Amputations involving bone loss, affecting the Thumb(s).
Final narrative
An employee was cleaning the rice cake machine. He then went to move the machine when it caught and amputated his thumb.
HospitalizedAmputation Thumb(s) Food and beverage processing machinery n.e.c.
A temporary employee turned off a planer machine, opened the housing, and began clearing a jam. The machine's spinning blade caught his right hand and degloved the index finger.
An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.
A production sanitation employee was pre-rinsing an incline conveyor and noticed cheese stuck between the belt idler. The employee went to remove the cheese and their glove got caught and pulled their left forearm into the conveyor. The employee's arm was fractured. The machine was not locked out/tagged out at the time.
More severe injuries in this industry (NAICS 311811)
An employee was operating a stretch wrap machine in the packaging area when his little finger was caught in the machine's chain mechanism. He sustained a fracture to the tuft of the finger and was hospitalized. The machine was unguarded at the time of the incident.
On August 12, 2025, an employee was performing maintenance on a motor and suffered an amputation to the left index fingertip, as well as a laceration to the left middle finger.
An employee was performing sanitation tasks and adjusting a valve by tapping it with a rubber mallet. The valve came apart and the employee was sprayed with 180-190-degree water. He was hospitalized with thermal burns to multiple parts of the body.
An employee was cleaning ovens from a three-step ladder. The ladder slipped, causing employee to lose balance and fall to the floor, suffering a broken left leg.
An employee suspected there was a problem with the filler machine during the clean-in-place process. He contacted moving parts and sustained the amputation of his left middle finger. The machine was running at the time.
An employee was installing fence posts when they stepped into a recently dug hole that was not visible due to rainfall. The employee's leg was fractured.
An employee assisted in cleaning material from a conveyor pit. After the pit was cleaned, the employee proceeded to replace metal safety plates to ensure other employees did not fall into the pit. While replacing one of the last plates, the employee mis-stepped and fell approximately 5 feet into the pit. The employee was hospitalized with back/side bruising, elbow bruising, bone bruises, and/or fractured ribs.
An employee was walking on the sidewalk. When they stepped off the curb, they fell to the ground, resulting in fractures to their tibia, fibula, and a metatarsal.