Federal OSHA recorded a severe workplace injury
at Got-Rack, 5210 CAUSEWAY BLVD., TAMPA, FLORIDA 33619
on — Fractures , affecting the Foot(feet) and leg(s) unspecified.
Final narrative
Employees were building a sample racking system when a structural piece collapsed and struck one of them. The employee suffered a broken leg/foot.
Hospitalized Foot(feet) and leg(s) unspecified Parts and materials unspecified
The injured employee was assisting five other employees with bracing a wall panel that was being stood up. Another employee slipped on frost on the floor surface. The employees went to evacuate the area in anticipation of the wall panel falling over. The injured employee went to jump through a window opening within the wall panel and their lower half was crushed by the falling wall panel. The employee sustained a fractured pelvis.
An employee was helping to move a 1,300-pound coil on a cart. The steel caster hit a crack in the concrete, the weld holding the caster onto the cart broke, and the coil and cart tipped over onto the employee. He was hospitalized with a laceration on his forehead and a pelvic fracture on his right side.
An employee was attempting to lift a steel beam from a horizontal, stacked position to a vertical position using a crane. They had placed two hooks on the east side of the beam on the flange. As the employee was hoisting the crane, the beam began to shift and pulled the employee forward onto the stack. When the material shifted, the hooks released and the material fell, pinning the employee between the two beams. The employee was hospitalized with soft tissue contusions on their proximal right thigh and interior left thigh.
An employee was moving a tensile strength test device with a dolly. The device fell from the dolly onto the employee's right leg, causing a compound fracture.
On August 13, 2025, an employee was feeding wire through a junction box to feed a 120-volt circuit near a 480-volt bus duct. The bus duct suddenly combusted, and the employee suffered burns to his left hand and upper body. He was hospitalized.
An employee was operating a brake press and making the final bend on a steel part. Her right middle finger got caught between the part and the top punch as it bent the part upward. The employee sustained a crush injury resulting in amputation of the fingertip.
An employee was feeding scrap metal into a chipper when his right hand was squeezed against a metal component of the machine. He suffered an amputation to the right index finger at the second joint.
On June 18, 2025, an employee working as a millwork installer was cutting shims using a circular saw. The saw hit a knot in the wood and jumped, cutting the palm of the employee's left hand and causing partial amputations to three fingers. The employee was hospitalized.
An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.
An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.
An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.
An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.