AdvanSix, Inc.

Exposure through intact tissue · Chemical burns, corrosions degree unspecified

Federal OSHA recorded a severe workplace injury at AdvanSix, Inc., 2501 Margaret Street, PHILADELPHIA, PENNSYLVANIA 19137 on — Chemical burns, corrosions degree unspecified, affecting the Thigh(s).

An employee was lifting a level controller that had been on a vertical tank. Residual phenol-containing liquid dripped onto his right thigh, causing a chemical burn. He was hospitalized.

Hospitalized Thigh(s) Phenol

AdvanSix, Inc.

An employee was troubleshooting a leak on a low pressure (less than 50 PSI) condensate line in the oxidation area of the plant. He was working to remove insulation around a valve when either the valve or the line failed, and hot condensate contacted his right arm, right abdomen area, and the front of both legs, resulting in second- and third-degree burns.

AdvanSix, Inc.

On May 18, 2023, an employee was traveling between two areas when a partially frozen slug of phenol containing material from an overhead leak (phenol/sulfate water) dislodged and struck his hard hat and jacket. Liquid then splashed onto his neck and face and the employee sustained first-and second-degree burns to the right side of his neck and torso.

View AdvanSix, Inc.'s full OSHA safety record →

Sharp International Services, LLC

An employee was removing a hose from a chemical tank after filling the tank with hexamethylenediamine (HMD). He checked the line to ensure that the hose was clear, then disconnected the hose at the connection. Residual chemical sprayed onto his face, causing a second-degree burn. He was hospitalized.

PCI Nitrogen, LLC

A shipping/receiving operator was working on a loading rack, loading a railcar. A 2-inch discharge cap failed and released pressure along with sulfuric acid from the railcar. The acid sprayed onto the employee, who suffered burns to the chest and the lower facial area. The employee was hospitalized.

American Equipment Systems, LLC

An employee was pressure washing truck scales when they were splashed with water and an unknown chemical on their leg and immediately experienced a burning sensation. The employee was hospitalized with a chemical burn and required surgery.

Innovative Chemical Technologies

An employee was on a ladder disconnecting a 1-inch hose, known to have last carried acrylic acid that had been drained. When the hose was disconnected, residual acid dripped onto the employee's shoulder/arm area, causing a second-degree chemical burn.

Pen Gulf, Inc.

Employees were removing scaffolding that was used to repair an ion exchange tank. The line was undergoing the regen process when a piece of scaffold struck a PVC pipe that transported hydrochloric acid (HCl). The injured employee was placing material inside a scaffold rack when he was sprayed in the face with HCl and sustained chemical burns to his eyes, face, chest, right arm, and left leg.

General Polymeric Corporation

An employee was monitoring a rotary press when his left hand became caught in the machinery. The employee's left middle finger was amputated at the distal interphalangeal joint.

MCM Plastics, Inc.

An employee was sweeping in an area with powdered PVC on the floor and began having difficulty breathing and coughing up blood, The employee was hospitalized for inhalation of PVC.

Lawter Inc.

An employee was working on a pastillator machine, which processes resin-based materials into solid pastilles. His right hand became caught between the feed roller (operating at approximately 350 F) and the cooling belt. The employee s glove and shirt sleeve adhered to his arm due to the heat. The employee sustained third-degree burns to his right hand and forearm, requiring hospitalization and surgery.

AdvanSix, Inc.

An employee was troubleshooting a leak on a low pressure (less than 50 PSI) condensate line in the oxidation area of the plant. He was working to remove insulation around a valve when either the valve or the line failed, and hot condensate contacted his right arm, right abdomen area, and the front of both legs, resulting in second- and third-degree burns.

Rochling Machined Plastics

An employee was replacing a fan on a cooling unit. As he went to adjust a pump, the unit caught his right hand and the fan blades severely lacerated his index finger. He underwent a medical amputation to the finger.

Main Line Clinical Labs

An employee was closing a door when the door closed on their right index finger, resulting in a fingertip amputation.

Ardent Mills

An employee was walking into the motor control center (MCC) room when his right ring finger was caught in the hinge of a doorway. He sustained an open phalanx fracture, which resulted in a partial amputation above the first knuckle.

Zimmerman & Herr

An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.

McAneny Brothers, Inc.

An employee was pulling down a broken skid with a forklift. When the employee backed up the forklift to get the forks out of the skid he pulled down, he contacted the forks of another parked forklift, fracturing both of his legs. He was hospitalized.

Metz Culinary Management LLC

An employee was carrying cups back to the kitchen when her foot got caught on a cart and she fell face-first. During the fall, a piece of glass from a cup cut the inside of her mouth, severing an artery. She also sustained a laceration on her lower lip. The employee was hospitalized.