Federal OSHA recorded a severe workplace injury
at BEK Consulting, LLC, Apple Creek lift station, BISMARCK, NORTH DAKOTA 58503
on — Nonfatal 'crushing' injuries, affecting the Other finger(s) n.e.c..
Final narrative
An employee was installing a metal rail when three fingers on their right hand were crushed between the rail and another object. The employee was hospitalized.
Hospitalized Other finger(s) n.e.c. Beams and rails metal
On October 20, 2022, an employee was unloading a jumping jack compactor from the end of a trailer, which was approximately 18 inches high. The employee slipped on loose gravel and fell. The compactor fell off the trailer and landed on his right hand, crushing his right middle and ring fingertips. The employee was taken to the hospital, where the injured fingertips were amputated.
A crew was installing drilled micropiles alongside an outdoor covered deck foundation. The injured employee was working the front of the drill when a loose section of casing dropped onto the tip of a rig wrench and pulled the wrench down to an embedded casing. The employee's left little finger was caught between the rig wrench and the embedded casing and was amputated above the top knuckle.
An employee was checking a pole-type transformer tank for leaks. A hydraulic clamping device was lowered onto his right thumb and crushed it against the sharp edge of the bottom of the tank. He suffered a partial transphalangeal amputation to the thumb.
An employee had been cleaning the work area. While lifting a saw, the employee's index finger was lacerated by the saw blade. A tendon was cut and required surgery.
An employee was installing a hydraulic extension cylinder in a tow truck when their leg was caught between the cylinder and the truck frame. The employee was hospitalized with a broken tibia, which required surgery.
An employee was sorting sucker rods. His right hand was caught in the area where the rod hits up against the frame and his index fingertip was amputated just below the nail.
More severe injuries in this industry (NAICS 237110)
An employee was moving a tensile strength test device with a dolly. The device fell from the dolly onto the employee's right leg, causing a compound fracture.
On October 7, 2025, employees were conducting trenching operations for the installation of a new sewer line system. The excavator's bucket was detached and put inside the trench as it was being exchanged for a different-sized bucket. An employee entered the trench with a shovel to move some dirt located at the front end of the pipe. The excavator bucket shifted and slid, striking the employee s right foot and trapping it against the ground. The employee sustained a fractured right tibia.
Employees were working to dislodge a large truck that was stuck in a rut using tow straps and a front-end loader with the bucket removed. An employee connected the straps to the loader and truck and another employee slowly engaged the loader to close the coupler. The injured employee's arm became caught in a pinch point. The employee was hospitalized with a fractured arm.
An employee was lifting a piece of 30-inch line stopping equipment using a jack screw. A lifting eye weld snapped and the load dropped. The end of the jack screw then landed on the employee's heel and crushed it. The employee was hospitalized.
An employee was on the ground working to close a trailer door. The door was caught by the wind and blew the employee backward. He landed on his back and sustained four fractured ribs, requiring hospitalization.
An employee was walking on top of boiler to close a valve. The employee fell off the boiler and landed on the floor, sustaining fractured ribs. The employee was hospitalized.
An employee was exiting a loader and coming down the ladder. His hand slipped off the railing and he fell backward onto sandy ground, landing on his side. The employee was hospitalized with a fractured pelvis and a rotator cuff tear.