105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

HEPNER AIR FILTER SERVICE, INC.

Struck by running powered equipment during maintenance, cleaning, testing · Amputations involving bone loss

Federal OSHA recorded a severe workplace injury at HEPNER AIR FILTER SERVICE, INC., 50 W. Bridge, BEREA, OHIO 44017 on — Amputations involving bone loss, affecting the Other finger(s) n.e.c..

An employee was replacing a screen on a rooftop HVAC unit when the rotating exhaust fan blade contacted their right index finger, resulting in a laceration that required hospitalization and the surgical amputation at the first knuckle.

Amputation Other finger(s) n.e.c. Fans, blowers wall, floor, ceiling, ventilation

Envelope Seal Insulation, Inc

An employee was inspecting a generator whose radiator was leaking. He slipped, and a fan blade in the generator amputated his thumb and index finger.

CFL USA, LLC

A temporary employee turned off a planer machine, opened the housing, and began clearing a jam. The machine's spinning blade caught his right hand and degloved the index finger.

Bull Moose Tube

An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.

US Battery Manufacturing Company, Inc

A casting machine jammed. An employee's hand was caught in the machine, where a belt line caught and amputated the tip of his finger.

Sargento Foods Inc

A production sanitation employee was pre-rinsing an incline conveyor and noticed cheese stuck between the belt idler. The employee went to remove the cheese and their glove got caught and pulled their left forearm into the conveyor. The employee's arm was fractured. The machine was not locked out/tagged out at the time.

Advanced Air Technologies, Inc.

An employee was using a multimeter to ensure proper power supply to a newly repaired rotary screw air compressor before running a voltage test. An electrical arc flash occurred, resulting in burns to both the employee's hands and their face.

Service-Tech Corporation

An employee was on the roof of a building, putting plastic around a dust collector, when their left middle finger was caught in a grinder insider the dust collector. The employee suffered a partial amputation to the left middle finger.

Diversitech Corporation

On August 4, 2025, an employee was fixing a jammed carousel and using a hook to manually adjust the carousel by hand. The hook slipped off and the employee fell to the concrete ground, resulting in hospitalization for a fractured right hip.

JF Filtration

An employee was changing an air filter when the door to the HVAC closed due to wind. The employee sustained an amputation to the left thumb at the nailbed.

K&N Engineering Inc

An employee was removing a filter from inside a mold when a switch malfunctioned and the mold clamped on his left hand, crushing it. The employee was hospitalized.

United States Postal Service

An employee was working to deliver mail to an apartment building. She was waiting for a customer to move, to obtain clearance to the mailboxes. The door swung inward and closed on her right little finger. The top half of her finger was surgically amputated.

Foundation Steel, LLC

An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.

GXO Logistics

On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.

Abbott Electric Inc

An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.

American Electric Power Company

An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.