Indirect exposure to electricity greater than 220 volts · Amputations involving bone loss
At a glance
Federal OSHA recorded a severe workplace injury
at Kline's Concrete and Site Work, LLC, U.S. Hwy 98, PERRY, FLORIDA 32347
on — Amputations involving bone loss, affecting the Toes(s), toenail(s).
Final narrative
On July 21, 2025, during the pouring of a concrete apron intended to connect property to a highway, an employee was using a bull float on an aluminum pole. They lifted the the pole and it made contact with an active power line. The employee sustained an electrical shock, burns to the hands, and electric current-induced amputation of six toes.
Amputation Toes(s), toenail(s) Power lines, transformers, convertors
An employee was guiding the pouring end of a concrete pump truck's boom while standing on top of 4-foot wall forms. The boom contacted power lines and the employee was shocked. The employee sustained third-degree burns on the entry and exit path of the electricity, and also sustained first- and second-degree burns to their torso and legs.
An employee was cleaning a laptop charging cable when lightning struck. The employee began experiencing heart palpitations and hearing loss, resulting in hospitalization.
An employee was acting as a spotter for a forklift operator. While its forks were being raised, the forklift came into contact with a power line. The employee was touching the forklift's metal frame at the time and was shocked on the left palm. The employee suffered burns to both the left palm and the sole of the left foot.
A Smyrna Ready Mix delivery driver was delivering concrete to a job site. He backed his truck up to a pump truck, then began preparing it to transfer the concrete. The pump truck's boom moved and came into contact with a power line, which broke and fell onto the employee's delivery truck. The employee was knocked to the ground and suffered electrical burns to both arms and both feet.
An employee was clearing a right-of-way for utility lines when a small sapling was cut and fell, causing vines to pull a tree down and into power lines. The vines also became electrified and were contacting the employee's feet, shocking them. The employee became ill and experienced slurred speech and convulsions, resulting in hospitalization.
More severe injuries in this industry (NAICS 238110)
An employee was readjusting a safety hook to remove hardware from gang forms when his feet slipped. He fell to the ground, resulting in a broken left arm and wrist.
An employee was changing a boom pipe delivery system on a concrete pump truck. He tripped and fell from an elevated level to the ground, resulting in multiple leg fractures.
An employee was reading numbers off a belt that feeds a plant. He reached his hand up and the belt caught his finger, resulting in a finger amputation.
An employee was guiding the pouring end of a concrete pump truck's boom while standing on top of 4-foot wall forms. The boom contacted power lines and the employee was shocked. The employee sustained third-degree burns on the entry and exit path of the electricity, and also sustained first- and second-degree burns to their torso and legs.
An employee was holding a form board on a section of pavement. A skid steer backed into the employee's ankle, breaking it. The employee was hospitalized.
An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.
An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.
An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.
An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.