Federal OSHA recorded a severe workplace injury
at US Department of Justice, Federal Bureau of Prisons, USP Marion, 4500 Prison Road, MARION, ILLINOIS 62959
on — Amputations, avulsions, enucleations unspecified, affecting the Finger or thumb tip(s), nail(s).
Final narrative
An employee was working on an out-of-service forklift when his hand was caught in the door frame as the stuck cab door was being opened. The employee sustained a middle fingertip amputation.
Amputation Finger or thumb tip(s), nail(s) Forklift, order picker, platform truck powered
More severe injuries at US Department of Justice, Federal Bureau of Prisons, USP Marion
On 12/11/2017, at approximately 12:30 p.m., an employee was operating a rubber molding machine when he attempted to remove a left-over piece of rubber from the heated top plate. The employee's gloves made contact with the heated plate and melted to the surface. Before he was able to free himself, the molding machine began operating and pinned his right-hand fingers between the top and bottom plates for several seconds, amputating all four fingers and his thumb.
An employee was changing a die in a press when the die slipped and crushed the employee's left index finger. The employee sustained an open facture of the tuft of the left distal phalanx and a partial amputation.
An employee was diagnosing the lack of flow of product to a powder bin. The employee removed the rotary star valve below the bin. While he was reinstalling the valve, his right middle finger was crushed between its shaft and its housing. The finger was partially amputated.
On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.
An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.
An employee was conducting routine maintenance on a mixer. New lid pins had been installed, and the employee was rotating by hand to ensure they had been installed correctly. The employee's left middle finger was caught between the lid and top of a pin. The momentum from the mixer continued, causing a crushing injury to the finger. The employee underwent a medical amputation from the top knuckle to the tip of the finger.
More severe injuries in this industry (NAICS 922140)
An employee was working in the food service warehouse when he experienced chest pain, difficulty breathing, and lost consciousness. The employee sustained carbon monoxide poisoning.
An employee was responding to a physical altercation between two inmates when they slipped and fell on the ground, landing on their left arm. The employee was hospitalized with a compound fracture to their left forearm.
An employee was cutting grass on the grounds when grass became stuck under the mower. He was struck by the rotating mower blades while clearing the jam, resulting in lacerations to his right index and middle fingers.
An employee was changing a die in a press when the die slipped and crushed the employee's left index finger. The employee sustained an open facture of the tuft of the left distal phalanx and a partial amputation.
An employee was driving a boom lift (in the lowered position) in an exterior dock area. The lift s left wheels rolled onto base plates that covered a 3-foot-deep sump pit. The base plates failed, and one side of the lift dropped. The employee's left leg was caught under the lift basket, and he suffered a fracture to the lower leg including the ankle.