Federal OSHA recorded a severe workplace injury
at Dakota Protein Solutions, LLC, 27950 440th Avenue, FREEMAN, SOUTH DAKOTA 57029
on — Amputations, avulsions, enucleations unspecified, affecting the Finger or thumb tip(s), nail(s).
Final narrative
An employee was using a pneumatic impact wrench to tighten bolts on a brake press anvil. The impact wrench hooked up on something, causing the tool to rotate. This spun his left hand with it. Their index finger was pinched between the side handle of the tool and an anvil bolt on the press, resulting in an open fracture. The employee required a medical amputation of the fingertip.
Amputation Finger or thumb tip(s), nail(s) Wrenches, ratchets
After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.
An employee was using a vertical band saw to cut a thick piece of rubber material. While being cut, the material shifted, causing the employee s right hand to contact the moving blade. The employee's thumb was amputated below the knuckle. The employee was hospitalized, undergoing surgery.
More severe injuries in this industry (NAICS 311613)
A temporary employee was working to unclog butter from a butter melter pump. His right index finger was caught in the machine, and the fingertip was amputated. The machine was energized at the time.
An employee working at the reject conveyor was placing a product guide bar on the conveyor. This metal guide bar is placed on the side of the conveyor belt to funnel the product, preventing it from falling off the sides. As he was getting the attachment positioned, his left ring finger was caught between the conveyor belt and the conveyor belt frame. The employee's finger was fractured and partially amputated.
An employee was cleaning the area under a mobile elevated work platform. The platform lowered and struck the employee, resulting in a fractured right femur. The employee was hospitalized.
As an employee was opening an infeed valve. Hot tallow oil in the line above fell back down the pipe and came out of an open pressure relief valve, striking the employee on the thighs. The employee was hospitalized with second-degree burns to his thigh. Another employee sustained burns to their back but they were not hospitalized.
An employee was cleaning residue off a vertical band saw when the table top fell down from its upright position and partially amputated the employee's left thumb.
An employee was moving a tensile strength test device with a dolly. The device fell from the dolly onto the employee's right leg, causing a compound fracture.
An employee was walking past a crossover conveyor when a ramp came down and hit them in the back. The employee sustained a broken back vertebra, as well as a concussion, and was hospitalized.
An employee was using a hook tool to pull a pallet onto the lift gate of a tractor trailer. The hook detached from the underside of the pallet, causing the employee to fall backward off the lift gate. The employee landed on the concrete parking lot about 5 feet below, suffering fractures to the skull and two thoracic vertebrae.
An employee was walking on a truss table when he lost his balance and fell approximately 3 feet to the floor. The employee sustained a dislocated and fractured left ankle.