Ignition of clothing · Thermal burns second degree
At a glance
Federal OSHA recorded a severe workplace injury
at CFE Inc., Odessa-Montour Central School District, ODESSA, NEW YORK 14869
on — Thermal burns second degree, affecting the Hand(s), finger(s) unspecified.
Final narrative
An employee was cleaning a seam with weather membrane cleaner. The cleaner soaked into the employee's gloves, and they caught fire when a cigarette was lit. The employee suffered first- and second-degree burns to both hands and was hospitalized.
Hospitalized Hand(s), finger(s) unspecified Gloves, handguards except disposable, electric insulating
After repairing a piece of industrial equipment, an employee had brake-cleaning liquid on his gloves. A lighter ignited the liquid, and the employee's hands were severely burned.
The injured employee had been working with xylene in a paint booth and exited the paint booth for a smoke break. The employee dropped his lighter, causing his clothing to catch fire, possibly from xylene vapors. The employee sustained burns from their chest down to their thighs and was hospitalized.
An employee was charging the furnace when a spark from the furnace ignited and struck the employee's undershirt. The employee sustained burns to their lower back, hands, and front abdomen.
An employee was delivering materials. He was doing his pre-delivery inspection on the roof of the jobsite (a warehouse) when he fell through a plexiglass skylight. He landed on his feet on the concrete floor 14 feet below. The employee sustained fractures to his spine, left ulnar/radius, and right heel. The employee required surgery.
An employee was standing on a multi-purpose ladder installing head flashing over a window. Their feet were approximately 6 feet off the ground and three rungs from the top. The employee lost their grip on the drill they were using and the ladder tipped over. The employee fell from the ladder to the ground, resulting in a fractured left wrist, bruised chest, and lacerations to their face and lip.
An employee fell through a hole in the ceiling and suffered injuries to his side and right arm. When he fell, a piece of concrete fell with him and struck his arm. He was hospitalized.
An employee was laying glue on the corner of a three-story commercial flat roof to apply new thermoplastic polyolefin roofing material. He lost his balance and fell at least 35 feet to the concrete ground below. The employee sustained fractures.
An employee was operating a battery-powered broom to clean demolition debris off the top of the outermost bridge girder. The girder was approximately 11 feet above the demolition scaffold below. The employee fell approximately 8 feet to wind bracing below. The employee was hospitalized with a pelvis/tailbone fracture. Fall protection was in place at the time.
An employee slipped while descending in a stairwell, fell, and suffered multiple contusions/bruises to the head, neck, shoulders, knees, and back. She was hospitalized.
An employee was directing trucks as they entered and left a highway work zone. A vehicle struck them, resulting in multiple fractures and other injuries. The employee was hospitalized.